17
When the apparatus is put within a combined system it is directly connected to the input splitting and output
combining systems.
Before fully powering the apparatus, check that the output connections of the coaxial cable to the antenna
system are working.
In order to this it is possible to check the indication of the reflected power at low power levels. Only if the
SWR indication on the display is 0, the output power can be slowly increased. At maximum output power,
some watts might be shown as reflected power.
2.3 TELEMEASURING SOCKET CONNECTIONS
DB9 Socket
2.4 RS232, RS485 AND AGC SOCKET CONNECTIONS
PIN N°
SIGNAL TYPE
IN / OUT
FUNCTION
1
Analog
Output
FWD Power
2
Analog
Output
REF Power
3
Digital
Output
Temperature
4
Digital
Input
Interlock
5
GND
-
-
6 - 7
Digital
Output
Free contact (closed when alarm)
8
Digital
Input
0V = ON
5V = Normal
9
Digital
Input
0V = OFF
5V = Normal
PIN
1
2
3
4
5
6
7
8
9
FUNCTIONS
-
TxD
RxD
-
GND
-
-
-
-
RS232 - DB9 Socket
PIN
1
2
3
4
5
6
7
8
9
FUNCTIONS
-
Rx-
Rx+
5V
GND
-
Tx-
Tx+
-
RS485 - DB9 Socket