47
No.
OBIS
Description
RA
MA
MM
171
C.60.22
Event counter: over-current
-
+
+
172
C.60.23
Event counter: neutral current imbalance
-
+
+
173
C.60.30
Event counter: influence of magnetic field
-
+
+
174
C.60.31
Event counter: opening of meter cover
-
+
+
175
C.60.32
Event counter: opening of terminal cover
-
+
+
176
C.60.40
Event counter: clock setting
-
+
+
177
C.60.50
Event counter: internal error
-
+
+
178
C.61.10
Event timer: power outage
-
+
+
179
C.61.12
Event timer: over-voltage
-
+
+
180
C.61.13
Event timer: under-voltage
-
+
+
181
C.61.20
Event timer: power over-limit
-
+
+
182
C.61.21
Event timer: reverse current flow
-
+
+
183
C.61.22
Event timer: over-current
-
+
+
184
C.61.23
Event timer: neutral current imbalance
-
+
+
185
C.61.30
Event timer: influence of magnetic field
-
+
+
186
C.61.31
Event timer: opening of meter cover
-
+
+
187
C.61.32
Event timer: opening of terminal cover
-
+
+
188
C.69.1
Contractual power limit P
lim
-
+
+
189
C.70.0
Check sum of the firmware
-
+
+
190
C.70.1
Parametrization ID
-
+
+
191
C.70.3
Firmware execution rate (diagnostics parameter)
-
+
+
192
C.81.0
Baud rate settings of communication interfaces
-
+
+
193
C.90.1
User configuration bits
-
+
+
194
C.90.2
Display and IEC 62056-21 communication formats
-
+
+
195
C.90.3
S0 ports configuration
-
-
-
196
C.90.4
Billing period end denied time
-
-
-
197
C.90.9
Meter relays output state
-
-
-
198
F.F.0
Error code
-
+
+
199
P.1.0
Load profile
-
+
+
200
P.97.0
Power failure (outage event) log
-
+
+
201
P.98.12
Voltage swell (Over-voltage) event log
-
+
+
202
P.98.13
Voltage sag (Under voltage) event log
-
+
+
203
P.98.14
Internal main relay event log
-
+
+
204
P.98.20
Power over limit event log
-
+
+
205
P.98.21
Reverse current flow event log
-
+
+
206
P.98.22
Over-current event log
-
+
+
207
P.98.23
Neutral current imbalance event log
-
+
+
208
P.98.30
Influence of magnetic field event log
-
+
+
209
P.98.31
Opening of meter cover event log
-
+
+
210
P.98.32
Opening of terminal cover event log
-
+
+
211
P.98.40
Clock setting event log
-
+
+
212
P.98.41
Parameter change event log
-
+
+
213
P.98.43
Failed authentication log
-
+
+
214
P.98.50
Internal error event log
-
+
+
215
P.98.51
Tariff changing event log
-
+
+
216
P.98.52
Load profiles resets event log
-
+
+
217
P.98.60
Firmware upgrade event log
-
+
+
Current date (OBIS = 0.9.2) may be indicated with different date delimiters: “” or “ ” (e.g.
YYMMDD
or
YY MM DD
). Delimiter may be chosen during meter parameterization. You
may find different delimiters in different examples further in this manual.
11.1 Reserved-automatic (
RA
) display sequence
Even if G1B meter is disconnected from network voltage, data still may be reviewed: press and
hold scroll push-button for 2 to 5 seconds, and
RA
will start. LCD test, time, date and total energy
register value (OBIS 1.8.0 or 15.8.0 –depends on meter modifications) will be indicated on LCD.