66
No.
OBIS
Description
L
C
D
62
05
6-
21
P
M
C
F
DLMS/COSEM
period
122.
8.6.M*VV
Maximum demand Q4 [kvar] of tariff M=[1T6] in previous billing
period
r
r
4-
r
r
-
123.
8.8.0
Total energy R4 [kvarh], current value
r
r
3-
r
r
-
124.
8.8.0*VV
Total energy R4 [kvarh], value at the end of previous billing period
r
r
3-
r
r
-
125.
8.8.T
Total energy R4 [kvarh] of tariff T=[1T6], current value
r
r
3-
r
r
-
126.
8.8.T*VV
Total energy R4 [kvarh] of tariff T=[1T6], value of previous billing
period
r
r
3-
r
r
-
127.
8.9.0
Billing period energy R4 [kvarh], current value
r
r
3-
r
r
-
128.
8.9.0*VV
Billing period energy R4 [kvarh], value of previous billing period
r
r
3-
r
r
-
129.
8.9.T
Billing period energy R4 [kvarh] of tariff T=[1T6], current value
r
r
3-
r
r
-
130.
8.9.T*VV
Billing period energy R4 [kvarh] of tariff T=[1T6], value of previous
billing period
r
r
3-
r
r
-
131.
10.0.1
Billing period reset
-
w
-
-
-
-
132.
11.0.0
Special days table
-
-
11-
r
r
-
133.
13.0.0
Activity calendar
-
-
20-
r
r
-
134.
13.7.0
Power factor cos(φ)
r
r
3-
r
r
-
135.
14.7.0
Frequency [Hz]
r
r
3-
r
r
-
136.
15.7.0
Instantaneous power |P| [kW]
r
r
3-
r
r
-
137.
16.7.0
Instantaneous power ±P [kW]
r
r
3-
r
r
-
138.
3.7.0
Instantaneous power +Q [kvar]
r
r
3-
r
r
-
139.
4.7.0
Instantaneous power -Q [kvar]
r
r
3-
r
r
-
140.
11.7.0
Instantaneous RMS value of current [A]
r
r
3-
r
r
-
141.
12.7.0
Instantaneous RMS value of voltage [V]
r
r
3-
r
r
-
142.
91.7.0
Instantaneous RMS value of current [A] in neutral
r
r
3-
r
r
-
143.
11.5.0
Average current [A]
r
r
3-
r
r
-
144.
12.5.0
Average voltage [V]
r
r
3-
r
r
-
145.
71.5.124
Average current THD
r
r
3-
r
r
-
146.
72.5.124
Average voltage THD
r
r
3-
r
r
-
147.
14.5.0
Average frequency [Hz]
r
r
3-
r
r
-
148.
C.1.0
Meter serial number (same as OBIS = 0.0.0)
r
r
1r
r
r
r
149.
C.1.1
Meter type
r
r
1r
r
r
r
150.
C.1.2
Ordering code
r
r
1r
r
r
r
151.
C.2.0
Parameterization counter
r
r
3-
r
r
-
152.
C.5.0
Internal operating status
r
r
3-
r
r
-
153.
C.7.5
Power outage counter
r
r
3-
r
r
-
154.
C.8.0
Time of operation
r
r
3-
r
r
-
155.
C.8.T
Time of operation of tariff T=[1T6]
r
r
3-
r
r
-
156.
C.50.1*NN
Active day program NN of energy tariffs
r
rw
1-
rw
r
-
157.
C.50.2*NN
Active week program NN of energy tariffs
r
rw
1-
rw
r
-
158.
C.50.3*NN
Active seasons NN of energy tariffs
r
rw
1-
rw
r
-
159.
C.51.1*NN
Active day program NN of demand tariffs
r
rw
1-
rw
r
-
160.
C.51.2*NN
Active week program NN of demand tariffs
r
rw
1-
rw
r
-
161.
C.51.3*NN
Active seasons NN of demand tariffs
r
rw
1-
rw
r
-
162.
C.52.1*NN
Passive day program NN of energy tariffs
r
rw
1-
rw
r
-
163.
C.52.2*NN
Passive week program NN of energy tariffs
r
rw
1-
rw
r
-
164.
C.52.3*NN
Passive seasons NN of energy tariffs
r
rw
1-
rw
r
-
165.
C.53.1*NN
Passive day program NN of demand tariffs
r
rw
1-
rw
r
-
166.
C.53.2*NN
Passive week program NN of demand tariffs
r
rw
1-
rw
r
-
167.
C.53.3*NN
Passive seasons NN of demand tariffs
r
rw
1-
rw
r
-
168.
C.54.0*NN
Permanent special days NN
r
rw
1-
rw
r
-
169.
C.54.1*NN
Leap-special-days NN
r
rw
1-
rw
r
-
170.
C.55.0
Tariff configuration bits
r
rw
1-
rw
r
-
171.
C.55.1
Date and time of activation of passive tariff table
r
rw
1-
rw
r
-
172.
C.55.2
Name of passive tariff table
r
rw
1-
rw
r
-
173.
C.60.11
Event counter: change in number of phases
r
r
3-
r
r
-
174.
C.60.12
Event counter: over-voltage
r
r
3-
r
r
-
175.
C.60.13
Event counter: under-voltage
r
r
3-
r
r
-
176.
C.60.14
Event counter: internal main relay
r
r
3-
r
r
-
177.
C.60.20
Event counter: power over-limit
r
r
3-
r
r
-
178.
C.60.21
Event counter: reverse current flow
r
r
3-
r
r
-
Summary of Contents for G1B Series