Installation and First Start-Up
- 16 -
5.3.2
Alignment of Sensor / Magnetic Tape
Since the active sensor surface is not in the center of the sensor housing, it should be ensured that the sensor
head is aligned and mounted such that the active sensor surface is in the middle of the magnetic tape. This is
achieved in a simple manner and without additional equipment. Just use the correct side of the sensor (see fig-
ure below) and install it flush with the magnetic tape.
Figure 7: Alignment of the Sensor
Standard (horizontal)
Option L (vertical)
5
Marker
Top view of the MB 20-20 magnetic tape
max. 0.8 mm
max. 0.8 mm
Top view
7.5
12.5
12.5
17.5
Cable outlet
The entire active sensor surface must be installed
within the permitted distance to the magnetic tape.
When mounting, please just make
sure that the sensor is flush with
the magnetic tape on this side.
Cable outlet