Technical Data
- 9 -
4.3
Technical Data Sensor
EMIX2 (Standard version)
Mechanical data
Housing material
Zinc die cast
Housing dimensions
L x W x H = 30 x 12.5 x 25 mm (
Suitable magnetic tape
MB20-20-10-1-R
Maximum measuring length
unlimited
Connection type
open cable ends (plug connectors optionally
Sensor cable
1.5 m standard length (others on request)
Weight
approx. 35 g without cable; cable approx. 60 g/m
Electrical data
Power supply voltage
+ 10 … 30 VDC or 5 VDC (depends on order information)
Residual ripple
10-30 V: <10 %; 5 V: +/-25 mV
Consumption
max. 150 mA at 10-30 V
Measurement principle
incremental
Output levels
10-30 VDC or 5 V-TTL line driver (depends on order information)
Output signals
A/A‘, B/B‘, Z/Z‘, push-pull, durable short circuit proof
System resolution
0.01 mm (at 4 edge triggering)
Repeat accuracy
+/- 0.01 mm
Output frequency
100 kHz per channel
Output current
max. 20 mA per channel
Operational speed
max. 4 m / s
System accuracy in µm at 20°C
+/- (20 µm +20 µm x L) L= measuring length in meters
Distance sensor / magnetic tape
max. 0.8 mm
Basic pole pitch
2 mm
Ambient conditions
Storage temperature
-25 … +85° C
Operation temperature
-10 … +70° C
(-25 … +85° C on request)
Humidity
max. 80 %, not condensing
Protection class
IP67