Product Features
- 10 -
6.3
Technical Data Sensor
FMAX2 / FMAX3 (Standard Version)
Mechanical Data
Measuring principle
absolute
Repeat accuracy
±1 increment
System accuracy in µm at 20° C
± (50 + 20 x L) L= Messlänge in Meter
Distance sensor - magnetic tape
max. 0.3 mm with cover tape,
resp. 0.6 mm without cover tape
Distance sensor - magnetic ring
max. 0.6 mm
Pole pitch FMAX2
1.5 mm (master track) / 1.5238 mm (nonius track)
Pole pitch FMAX3
2,0 mm (master track) / 2.0317 mm (nonius track)
Sensor housing material
zinc die cast
Sensor housing dimensions
L x W x H = 50 x 24 x 26 mm
Required magnetic tape FMAX2
AB20-15-10-2-R or
AB20-15-10-2-R-D (without cover tape) see Accessories
Required magnetic tape FMAX3
AB20-20-10-2-R or
AB20-20-10-2-R-D (without cover tape) see Accessories
Max. measuring length FMAX2
up to 192 mm
Max. measuring length FMAX3
up to 240 mm
Required magnetic ring FMAX2
MRR-00-061-050-006-0128 see Accessories
Required magnetic ring FMAX3
MRR-00-061-050-006-0128 see Accessories
Magnetic ring outer-Ø FMAX2
61.1 mm
Magnetic ring outer-Ø FMAX3
80.0 mm
Connections
open cable ends (connectors on request)
Sensor cable
1.5 m (others on request)
Sensor cable bending radius
60 mm
Weight
approx. 50 g; cable approx. 60 g/m
Electrical Data
Power supply voltage
10 … 30 VDC
Residual ripple
< 10 %
Current consumption
max. 150 mA
Interface
SSI (binary or Gray code)
Resolution
19 bit
Operating speed (linear)
max. 16 m/s
Rotation speed
max. 6.000 rpm
Environmental Conditions
Storage temperature
−25 ... +85 °C
Operating temperature
−25 ... +85 °C
Humidity
max. 95 %, non-condensing
Protection class
IP54 (IP67 with Option V)
Summary of Contents for FMAX2 Series
Page 25: ... 25 Notes ...