Figure 15 and Table 7 illustrate the learning of double sided floors:
Figure 15: CANopen learning of double sided floors
Table 7: Floor table as stored in CP in case of double sided floors
Floor No.
Position
First side
Second side
#1
1000
X
#2
3000
X
#3
4000
X
#4
7000
X
X
#5
10000
X
Concerning Teach mode manual it is strictly prohibited to implement a fully automatic learn trip
for LIMAX33 CP-00 in the lift control. The technician has to confirm manually at each floor that
the floor level is correct. The lift control is only allowed to send the CAN command to teach this
specific floor to the LIMAX33 CP-00 system in case the technician has confirmed.
#1 (1st side)
1000mm
Front floors
(first side)
Rear floors
(second side)
#2 (2nd side)
3000mm
#3 (first side)
4000mm
#4 (both sides)
7000mm
#5 (second side)
10000mm
CAN-Command:
Store actual
position as floor #4,
both sides
CP