Safety Functions
- 70 -
Figure 24 (below) illustrates the upper final limit switch, the upper pre-triggered stopping limit, the upper inspec-
tion limit and the distance s for ETSL-calculation when moving up related to the upper (limit switch-) reference
position.
Figure 24: Relations to the upper reference positions
Up per reference
position
car buffer
counterweight buffer
car
counter
weight
Offset
ETLS_UP
Distance „s“ for
ETSL calculation
Up per limit
switch
Offset upper
limit switch
Offset upper
inspection
limit switch
Offset upper
pre-triggered
stopping
system
Up per pre-triggered
stopping limit position
The upper
reference position
will normally be
learned when the
counterweight is
placed on the
buffer
car buffer
counterweight buffer
counter