7
Installation- Ducting Version
After having choosen the vent option, proceed as follows:
1
Remove the grease filters.
2
Remove the junction box cover. Remove either the top or
the back wiring knockout according the preference and
install an approved wiring clamp.
J-Box cover
Wiring clamp
3
Remove the duct knockouts using a flat blade screwdriver
and a small hammer. Use the screwdriver by knocking
out the pannel in similar fashion to a scalpel. Take care of
sharp edges.
I
ATTENTION
If it is intended to use the hood in the recirculating version do
not remove any duct knockouts and order the necessary
charcoal filter from your supplier.
R1 =
Remove rectangular duct knockout only.
R2 =
Remove semicircular and rectangular duct knockouts.
Rectangular
vertical discharge
R1
R2
R1
Round vertical
discharge
Rectangular
horizontal discharge
4
For rectangular ducted discharge installations only.
Attach exhaust adaptor/damper over knockout opening
with two exhaust adaptor screws.
Make sure damper pivot is nearest to top/back edge of
hood. Remove tape from damper flap.
NOTE
: The exhaust adaptor/damper can be installed up to 1 inch
on either side of the hood center to accommodate off-center
ductwork. In extreme offcenter installations, one end of the duct
connector may need to be trimmed to clear the electrical cable
clamp.
Exhaust transition/ damper
Top/back edge
Pivot
5
For round ducted discharge installations install 7” (17.8 cm)
transition with its screws (2).
NOTE
: The round transition can be installed up to 1 inch on
either side of the hood center to accommodate off-center
ductwork. In extreme offcenter installations, one end of the
duct connector may need to be trimmed to clear the electrical
cable clamp.
7” round transition