8

Mark holes 

Select the vent option that your installation will require 

and proceed to that section: 

Outside top exhaust 

(Vertical duct– 3 

1

4

”x 10” Rectangular)

Use the diagram or the hood as a template and mark the 

locations on the cabinet for ductwork, electrical wiring and 

keyhole screw slots.

Centerline

Electrical access 

hole (in cabinet 

bottom)

Wood shims (recessed 

bottom cabinets only)

Hood mounting screws (4)

13 

15

16

” (30” hood)

16 

15

16

” (36” Hood)

13 

15

16

” (30” hood)

16 

15

16

” (36” Hood)

Cabinet front

Cabinet bottom

12 

1

2

1

4

1

4

1

4

1

4

1

2

10 

1

2

5”

Vertical duct 

access hole

Outside top exhaust (Only recirculating version)

(Vertical duct–7” Round)

Use the diagram or the hood as a template and mark the 

locations on the cabinet for ductwork, electrical wiring and 

keyhole screw slots.

Wood shims (recessed 
bottom cabinets only)

Hood mounting screws (4)

13 

15 16

” (30” hood)

16 

15 16

” (36” Hood)

13 

15 16

” (30” hood)

16 

15 16

” (36” Hood)

Cabinet front

Cabinet bottom

12 

1 2

1 4

1 2

10 

1 2

5”

HOLE

Access hole for
7” round duct

Centerline

Electrical access hole

(in cabinet bottom)

8” DIA.

Outside rear exhaust

(Horizontal duct– 3 

1

4

”x 10” Rectangular)

Use the diagram or the hood as a template and mark the 

locations on the cabinet for ductwork, electrical wiring and 

keyhole screw slots. 

Centerline

Electrical access hole 
(in wall)

Cabinet 

bottom

Horizontal  duct 

access hole

Hood mounting 
screws (4)

Cabinet front

13 

15 16

” (30” hood)

16 

15 16

” (36” Hood)

13 

15 16

” (30” hood)

16 

15 16

” (36” Hood)

9 16

3

3 4

5

1 4

”5

1 4

12

7 16

1 8

Installation- Recirculating

Use the hood as a template and mark the locations on the 

cabinet for the electrical wiring and keyhole screw slots.

Since the hood is to be recirculated (not to be vented outside), 

do not cut out any vent openings in the wall or cabinet bottom.

Choose Venting Option

 

 

   

The hood can be set to vent outside or to recirculate air 

back into the kitchen. The plastic vent lever is located near 

the center of the hood opening.   

 

To vent to the outside, make sure the plastic vent lever is 

in the HORIZONTAL position (flat against the metal top 

of the hood). To recirculate air into the kitchen, make sure 

the plastic vent lever is in the VERTICAL position 

(flat against the plastic blower housing).

NOTE

: In order to change the vent lever position, you will 

need to pull the lever out slightly to clear the plastic tabs.

Hood shown lying upside down

Set for

outside venting

Set for

recirculating

Stop tab

Stop tab

For recessed bottom cabinet only

    

 

If the cabinets have front, side or back trim, make 2 wood 

shims the width of the trim and attach them to the cabinet 

bottom recess on both sides.    

 

 

See previous page for marking locations.

Wood shims

Cut holes at marked locations for duct and electrical 

wiring. For the vertical duct, cut out 

3

4

” extra toward the 

front of the cabinet so you can move the duct freely when 

installing the hood. It may also ease installation by cutting 

the hole 10

1

 2

” instead of 10”.

Drive a mounting screw (from the hardware packet)  

partway into each center of the narrow neck of the keyhole 

slots marked on the cabinet bottom.

Fix the wiring conduit to the hood.

Slide the hood back against the wall. Tighten the mounting 

screws. Be sure the screw heads are in the narrow neck of 

the keyhole slot. Connect Ductwork to hood.

Summary of Contents for ARIA EAI430SS

Page 1: ...utilisation d entretien et d installation Guía de instalación uso y mantenimiento READ AND SAVE THESE INSTRUCTIONS LISEZ CES INSTRUCTIONS ET CONSERVEZ LES LEA Y CONSERVE ESTAS INSTRUCCIONES LIB0131463 Printed in Mexico Models EAI430SS EAI436SS ...

Page 2: ...ty 12 APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING INSTALLATION MUST COMPLY WITH ALL LOCAL CODES IMPORTANT Save these Instructions for the Local Electrical Inspector s use INSTALLER Please leave these Instructions with this unit for the owner OWNER Please retain these instructions for future referenc...

Page 3: ...spaces within walls ceilings attics crawl spaces or garages IWARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCT WORK Install this hood in accordance with all requirements specified IWARNING To reduce the risk of fire or electric shock do not use this hood with any external solid state speed control device IWARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unatte...

Page 4: ...ower supply conduit at the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 BEFORE INSTALLING THE HOOD 1 For the most efficient air flow exhaust use a straight run or as few elbows as possible CAUTION Vent...

Page 5: ...ampers 1 4 5x13 mm 4 7 17 8 cm round transition 1 3 5x6 5 mm 1 Parts no supplied Tools Materials required Drill 11 4 3 0 cm drill bit 1 8 3 0 mm drill bit for pilot holes Pencil Wire stripper or utility knife Tape measure or ruler Caulking gun and weatherproof caulking compound Saber or keyhole saw Metal snips Screwdrivers Phillips Flat blade Optional accessories and consumable parts KIT Part 30 7...

Page 6: ...ting frame must be constructed Fittings material is provided to secure the hood to most types of walls ceilings However a qualified technician must verify suitability of the materials in accordance with the type of wall ceiling Before making cutouts make sure there is proper clearance within the ceiling or wall for exhaust vent Recommended installation height Hood installation height above cooktop...

Page 7: ...arge R1 R2 R1 Round vertical discharge Rectangular horizontal discharge 4 For rectangular ducted discharge installations only Attach exhaust adaptor damper over knockout opening with two exhaust adaptor screws Make sure damper pivot is nearest to top back edge of hood Remove tape from damper flap NOTE The exhaust adaptor damper can be installed up to 1 inch on either side of the hood center to acc...

Page 8: ... the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots Since the hood is to be recirculated not to be vented outside do not cut out any vent openings in the wall or cabinet bottom Choose Venting Option 1 The hood can be set to vent outside or to recirculate air back into the kitchen The plastic vent lever is located near the center of the ho...

Page 9: ...Electrical Code and local codes and ordinances in 1 2 conduit from service panel to junction box G E A B C F D A White wires B Black wires C UL listed wire connector D Green or bare ground wire E Home power supply cable or power cord accessory kit F UL listed or CSA approved strain relief G Green ground screw Connect black wire from service panel to black or red in junction box white to white and ...

Page 10: ... seconds You will hear a beep and all control lights will go on for 3 seconds The 3rd and 4th speeds will be Disabled Mainteinance Cleaning Do not spray cleaners directly to the control while cleaning the Hood The cooker hood should be cleaned regularly at least with the same frequency with which you carry out maintenance of the fat filters internally and externally Clean using the cloth dampened ...

Page 11: ...11 NOTE When removing for replacing for a new one do not remove Fixing Springs simply pull out one and rotate outwards Fixing spring Charcoal filter Grease filter top side ...

Page 12: ... other consumable part Normal wear of finish Wear to finish due to operator abuse improper maintenance use of corrosive or abrasive cleaning products pads and oven cleaner products WHO IS COVERED This warranty is extended to the original purchaser for products purchased for ordinary residential use in North America Including the United States Guam Puerto Rico US Virgin Islands Canada This warranty...

Page 13: ...13 ...

Page 14: ......

Reviews: