4
LIST OF MATERIALS
Removing the packaging.
I
CAUTION
Remove carton carefully, Wear gloves to protect against sharp edges.
I
WARNING
Remove the protective film covering the product before putting into operation.
Supplied Part
Pieces
Supplied Part
Pieces
Hood assembly and
LED lamps already installed
1
Mounting brackets
2
Metal spacers (for use when cabinet
depth is greater than 12”)
2
4.5x13 mm
8
Face plate Installation Brackets
4
4.2x15 mm
2
3.5x9.5 mm
6
3.5x9.5 mm
4
Torx #10 adapter
1
4.2x19 mm
8
Ø 6.4x18 mm washers
8
4.2x8 mm
8
Ø 4.2x12 mm washers
8
Parts no supplied
Tools/Materials required
•
Level
•
Drill
•
1
⁄
8
” (3.0 mm) drill bit
•
Pencil
•
Pliers
•
Tape measure or ruler
•
Caulking gun and weatherproof caulking compound
•
Flat-blade screwdriver
•
Phillips screwdriver
•
Saber or keyhole saw
•
Metal snips
•
Vent clamps
Parts needed
• 6” (15.2 cm) round metal vent system
Optional accessories and consumable parts
KIT
# Part
Recirculating Kit
KIT02770
Location requirements:
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating plate is located inside the liner behind the filter on the
left wall of the range hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult your
cooktop/ range manufacturer installation instructions before
making any cutouts.
Grounded electrical outlet is required. See “Electrical Requi-
rements” section.
The range hood is factory set for vented installations through
the roof or wall. For non-vented (recirculating) installations
see “Non- Vented (recirculating) Installation Through the
Soffit/Cabinet” in the “Prepare Location” section.
Recirculation Kit Part is available from your dealer or an authorized
parts distributor. All openings in ceiling and wall where range
hood will be installed must be sealed.
For mobile home installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
†
®
TORX is a registered trademark of Saturn Fasteners, Inc.
Summary of Contents for EAS422SS
Page 36: ......