9
• Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and ordinances,
in
1
⁄
2
” conduit from service panel to junction box.
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW GROUND
WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN RESULT IN
DEATH OR ELECTRICAL SHOCK.
• Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
• Close and secure junction box cover.
Complete installation
Replace filters.
Check operation of the hood.
If range hood does not operate:
• Check that the circuit breaker is not tripped or the house
fuse blown.
• Disconnect power supply. Check that wiring is correct.
To get the most efficient use from your new range hood, read
the “Maintenance” section.
Keep your Installation Instructions and Use and Care Guide
close to range hood for easy reference.
Description of the hood
2
4
3
1
3
1.
Blower and light controls
2.
LED lamps
3.
Grease filter handle
4.
Grease filter
Control
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the
hood before cooking and allow it to operate several minutes
after the cooking is complete to clear all smoke and odors
from the kitchen.
The hood controls are located on the center side of the hood.
Recessing Knobs
• You can hide control knobs by depressing them until flush
with the hood body.
• Pressing the knobs again will lower the knobs, and enable
the user to operate the lights and blower.
Controls
A
B
A. Lamps knob B. Blower knob
Operating the lamps
1. Turn the light switch to the “ON” position to turn the
range hood lights On.
2. Turn the light switch to the “OFF” position to turn the
range hood lights Off.
Operating the blower
1. Turn the blower switch at “1” to turn the range hood on.
2. Turn the blower switch to the desired speed position.
3. Turn the blower switch to the “MAX” position to turn the
range hood on High.
4. Turn the blower switch to the “OFF” position to turn the
range hood blower Off.
Auto On blower
The range hood is equipped with a sensor to automatically turn
on the blower when excessive heat is detected in the control
area. When the blower switch is in the “Off” position, this sensor
will turn the blower to high speed when necessary. When the
heat decreases, the blower will turn off. When the blower
switch is in the On position, the heat sensor is not active and
the range hood functions normally.