7
Ducting Options and Examples
Closely follow the instructions set out in this manual.
All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined.
Venting methods
The hood is equipped with a transition
B
for discharge of fumes to the outside (
Ducting version
).
Minimum Duct Size (Ducting/Ductless version): 8" Round Pipe.
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be
constructed.
Fittings material is provided to secure the hood to most types of walls/ceilings.
However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
Hood installation height above cooktop is the users preference. The lower the hood is above the cooktop, the more efficient the
capturing of cooking odors, grease and smoke.
CAUTION:
FOR 8’ CEILINGS: MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS AT 30
"
(76,2 CM)
MINIMUM
ABOVE THE
COOKING
SURFACE.
FOR 9’ CEILINGS: MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS AT 35” (88,9 CM)
MINIMUM
ABOVE THE
COOKING S
URFACE.
Check your ceiling height and the hood height maximum before you select your hood.
Summary of Contents for EEG636SS
Page 6: ...6 Dimensions and Clearances Mín 30 1 5 Max 42 27 2 3 8 13 13 16 12 1 8 36 42 ...
Page 20: ...20 Dimensions et Dégagement Mín 30 1 5 Max 42 27 2 3 8 13 13 16 12 1 8 36 42 ...
Page 34: ...34 Dimensiones y Espacios libres Mín 30 1 5 Max 42 27 2 3 8 13 13 16 12 1 8 36 42 ...
Page 44: ......
Page 45: ......