10
1. Blower and LED lamp controls
2. LED lamps
3. Grease filter handle
4. Grease filters
5. Perimetric cover
6. Duct covers
Control
1
2
3
4
5
6
1.
Button ON/OFF motor (stand by)
2.
Button for low speed (suction power) selection
When flashing, it indicates that you must wash the grease filter.
3.
Button for medium speed (suction power) selection
4.
Button for high speed (suction power) selection
5.
Button for intensive speed (suction power) selection
It lasts 5 minutes then it returns to medium speed (suction power).
6.
Button ON/OFF lighting
Press briefly to switch on or off the lighting of the hood.
Press and hold to adjust the intensity of the light.
Indicators of filter saturation:
At regular time intervals, the hood indicates the need of
performing filter maintenance.
Button
on with steady light:
Perform grease filter maintenance.
Button
flashing:
Perform activated charcoal filter maintenance.
NOTE
: Filter saturation signal is visible within the first minute
after switching off the hood; within this time, the reset of
saturation indicators must be performed.
Reset of filter saturation indicators:
Press and hold the button
Activation of saturation indicator activated charcoal filter:
NOTE
: This operation must be performed with the hood off.
This indicator is normally deactivated; press and hold the
button
to activate the function: the button lights up with
steady light.
To deactivate the function, press and hold the button
,
the button lights up flashing.
CFM Reduction System
Before operating your hood:
Some States and Provinces of the US & Canada restrict the
maximum exhausting airflow of range hoods. Airflow is measured
as cubic feet per minute (CFM). These maximum levels allowed
are detailed in the local code of your area. Please check local
codes to find out if you need to restrict the maximum airflow
of your hood. If your local code mandates a maximum airflow
level below the maximum airflow of this hood (i.e. 600 CFM),
please execute the procedure below to reduce the maximum
airflow.
1
5
1
Turn the motor OFF.
2
Press the ON/OFF (1) and Intensive speed (5) buttons
together for 3 seconds.
You will hear a beep and all control lights will illuminate
for 3 seconds.
This action will Disable speeds 3 and 4 and effectively
lower the Maximum airflow to < 300 CFM.
3
Locate the CFM certification sticker in the hardware pack.
4
Peel and Affix this sticker to a visible area in the blower.
This sticker provides official certification to your local
inspector that this hoods maximum airflow has been
reduced to < 300 CFM.