8
Complete the installation
ONLY FOR RECIRCULATING VERSION
(Using Recirculating Kit model KIT0141925)
When used in recirculation mode, To Reduce the Risk of Fire
and Shock use only conversion kit Model KIT0141925.
Air deflector installation
• Assemble the air deflector with the duct cover bracket
with 4 assembly screws provided as shown.
• Measure from the bottom of the air deflector to the
bottom of the hood outlet, as shown:
Dimension
to measure
Wall
outlet
• Cut the duct at the measured size.
• Uninstall the air deflector removing the 4 assembly screws.
• Slip the duct onto the bottom of the deflector.
• Place the assembled deflector and duct over the exhaust
outlet from the hood.
• Place charcoal filters. See “Maintenance” section.
Electrical connection
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1
Disconnect power.
2
Remove terminal box cover.
3
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
1
⁄
2
” strain relief.
B
A.
Knockout
B.
Junction box cover
A
4
Run home power supply cable through strain relief, into
terminal box.
A
B
C
D
E
F
A.
Home power supply cable
B.
UL listed or CSA approved
strain relief
C.
Black wires
D.
UL listed wire connectors
E.
White wires
F.
Green (or bare) and
yellow-green ground wires
5
Use UL listed wire connectors and connect black wires
(C) together.
6
Use UL listed wire connectors and connect white wires (E)
together.
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
7
Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box