17
Controls
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Note:
Hood retains last speed setting when aspiration
switch is turned off.
Description of control panel
1. Light Button
• Press lamp button to turn ON the light on High
Intensity (Lamp state previously OFF).
• Press lamp button to turn ON the light on Low
Intensity (Lamp state previously ON).
• Press lamp button to turn OFF the light (Lamp state
previously ON).
2. Timer Button
• The default timer setting is 10 minutes, and it can be
adjusted between 60 minutes and 1 minute.
•
After pressing the timer button, the control enters to a
timer setup mode, and user can adjust the timer
countdown time with the “+” and “-” buttons within 5
seconds. The timer can be initiated immediately
pressing the timer button, after setting the timer
duration or pressing the timer button twice (default 10
minutes setting).
• If no action occurs within 5 seconds, the countdown
will start.
• During the timer setup the “+” and “-” buttons are
dedicated to the timer and no motor action will occur.
• Once the timer is initiated, it can be cancelled by
pressing the timer button again.
3. Display
•
Shows the hood settings.
• The display will be lit at low intensity when the hood
is not operating.
Pressing any key the display will light up at high
intensity.
• The display will be lit at high intensity when the hood
is operating.
If no key is pressed within a minute the display will
return to being lit at low intensity.
4. “-” Button. Speed Decrease / OFF
• This button is used to decrease the fan speed, or
turn OFF the fan.
• The fan will turn OFF if the “-” button is pressed and
the hood was in the first speed.
• If the fan is at second speed and the “-” button is
pressed, the fan will be set to first speed.
• If the fan is at third speed and the “-” key is pressed,
the fan will be set to second speed.
• If the fan is at fourth speed and the “-” button is
pressed, the fan will be set to third speed.
• If the fan is OFF and the “-” button is pressed, the
control backlight will light up.
5. “+” Button. Speed Increase / ON
• This button is used to increase the fan speed, or turn
ON the fan.
• The fan will turn ON if the “+” button is pressed and
the hood was OFF.
• If the fan is at first speed and the “+” button is
pressed, the fan will be set to second speed.
• If the fan is at second speed and the “+” button is
pressed, the fan will be set to third speed.
• If the fan is at third speed and the “+” button is
pressed, the fan will be set to fourth speed.
• If the fan is at fourth speed and the “+” button is
pressed, a beep will sound.
Clock programming
• The clock can be reprogrammed at any time except
during an active timed function.
• The clock can be displayed in a twelve hour format and
valid clock times are from 1:00 to 12:59.
• The clock can be reprogrammed pressing the “
Timer
”
button for 3 seconds, and after, the clock can be
adjusted with the “+” and “-” buttons.
• The user can have minute increments / decrements of 1
minute, but if the user keep pressing the “+” / ”-” buttons
for more than 1 second, the increments / decrements will
be of 5 minutes.
During this option the control will round to the nearest 5
minutes.
• The user can finish on reprogramming the clock pressing
the “
Timer
” button.
• After 1 minute of no button pressed the control will
accept the programmed clock time and will add one
minute to the set clock.
Grease filter saturation alarm (Optional)
• After thirty fan functional hours, the display will show
“
Grease Filter
” if the fan is active.
When this icon is shown in the display, the grease filters
installed are required to be washed.
• To reset the grease filter saturation alarm the user must
press the “+” button for 5 seconds, after this action the
icon “
Grease filter
” is not displayed, and the hood has
the normal display operation.
Charcoal filter saturation alarm (Optional)
• After one hundred and twenty functional hours of the fan,
the display will show “
Charcoal Filter
” if the fan is
active. When this icon flashes on display, the charcoal
filters installed are required to be replaced or
reactivated.
• To reset the charcoal filter saturation indication the user
must press the “-” button for 5 seconds, after this time
the icon “
Charcoal filter
” is not displayed and the hood
has the normal display operation.
Audible signal activation and deactivation
• The audible signals can be activated or deactivated
pressing the “
Light
” button for 5 seconds.
• If the audible signal is activated, a tone must sound and
the “
Snd
” symbol must appear on the display for 3
seconds.
• If the audible signal is deactivated, the “
Snd
” symbol
must appear on the display for 3 seconds and no tone
must sound.
Summary of Contents for EPC632SS
Page 6: ...6 Dimensions and Clearances ...
Page 26: ...26 Dimensions et Dégagement ...