7
Ducting Options
Closely follow the instructions set out in this manual�
All responsability, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined�
Ducting version
This range hood is factory set for venting through the roof
or through the wall� The vent system needed for installation
is not included�
A 6” (15�2 cm) round vent system is recommended�
Roof Venting
Wall Venting
A
B
A
B
A. 6” (15.2 cm) vent through the roof
B. Roof cap
A. 6” (15.2 cm) vent through the wall
B. Wall cap
Ductless (Recirculating)
In cases where it should not
be possible to discharge
cooking fumes and vapour to
the outside�
You can apply the
recirculating venting
method by purchasing the
Recirculation Kit�
A
B
A. 6” (15.2 cm) vent through the cabinet
B. Round recirculating grid
Preparation
Fittings material is provided to secure the hood to most types
of walls/ceilings�
However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling�
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent�
I
CAUTION
For gas cooktop & range installations: Mount the hood so the
bottom is at least 27”(68,5 cm) above the cooking surface�
For electric/induction cooktop & range installations: Mount
the hood so the bottom is at least 24” (61 cm) above the
cooking surface�
There is no maximum mounting height, however, we
recommend mounting the hood no greater than 36” (91�4
cm) above the cooking surface� For every inch (2�54 cm)
above 36” (91�4 cm), fume and moisture capture efficiency
diminishes at an increasing rate and may not deliver an
acceptable level of ventilating performance�
This hood is intended for household use�
PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC
APPLICATION� Check your ceiling height and hood height
before selecting your hood�