8
Connect Vent System
1
Install transition on top of hood (if removed for shipping)
with 4 - 4 x 8 mm sheet metal screws.
A
B
A. Vent transition
B. 4 x 8 mm screws
For vented installations only:
1
Fit vent system over the exhaust outlet.
2
Measure from the bottom of the air deflector to the
bottom of the hood outlet. Cut the ductwork at the
measured dimension.
Dimension
to measure
Roof outlet
Wall
outlet
3
Seal connection with clamps.
4
Check that back draft dampers work properly.
Electrical Connection
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1
Disconnect power.
2
Remove terminal box cover.
3
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
1
⁄
2
” strain relief.
A
B
C
A.
Knockout
B.
Junction box cover
C.
Junction box cover screws
4
Run home power supply cable through strain relief, into
terminal box.
A
B
C
F
E
D
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and
yellow-green ground wires
5
Use UL listed wire connectors and connect black wires
(B) together.
6
Use UL listed wire connectors and connect white wires (A)
together.
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO
CAN RESULT IN DEATH OR ELECTRICAL SHOCK.
7
Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (D) in terminal box
using UL listed wire connectors.
8
Tighten strain relief screw.
9
Install terminal box cover.
10
Check that all light bulbs are secure in their sockets.
11
Reconnect power.