background image

 

Installation 

• 

The minimum distance between the supporting surface for 

the cooking equipment on the hob and the lowest part of the 

range hood must not be less than 45cm from electric cookers 

and 50cm from gas or mixed cookers. 

If the instructions for installation for the gas hob specify a 

greater distance, this must be adhered to. 

• This appliance is marked according to the European 

directive 2012/19/EC -  UK SI 2013 No.3113 on Waste 

Electrical and Electronic Equipment (WEEE).  

• By ensuring this product is disposed of correctly, you will 

help prevent potential negative consequences for the 

environment and human health, which could otherwise be 

caused by inappropriate waste handling of this product. 

• The  symbol 

  on the product, or on the documents 

accompanying the product, indicates that this appliance may 

not be treated as household waste. Instead it should be taken 

to the appropriate collection point for the recycling of electrical 

and electronic equipment. Disposal must be carried out in 

accordance with local environmental regulations for waste 

disposal. 

• For further detailed information regarding the process, 

collection and recycling of this product, please contact the 

appropriate department of your local authorities or the local 

department for household waste or the shop where you 

purchased this product. 

 

Appliance designed, tested and manufactured according to: 

• Safety: EN/IEC 60335-1; EN/IEC 60335-2-31, EN/IEC 

62233. 

• Performance: EN/IEC 61591; ISO 5167-1; ISO 5167-3; ISO 

5168; EN/IEC 60704-1; EN/IEC 60704-2-13; EN/IEC 60704-3; 

ISO 3741; EN 50564; IEC 62301. 

• EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2; 

EN/IEC 61000-3-2; EN/IEC 61000-3-3. 

Suggestions for a correct use in order to reduce the 

environmental impact:  Switch ON the hood at minimum 

speed when you start cooking and kept it running for few 

minutes after cooking is finished. Increase the speed only in 

case of large amount of smoke and vapor and use boost 

speed(s) only in extreme situations. Replace the charcoal 

filter(s) when necessary to maintain a good odor reduction 

efficiency. Clean the grease filter(s) when necessary to 

maintain a good grease filter efficiency. Use the maximum 

diameter of the ducting system indicated in this manual to 

optimize efficiency and minimize noise. 

 

 

 

 

 

 

 

 

 

Use 

!Your hood has been designed to be used in suction 

version only  

 

 Extraction version 

In this case the fumes are conveyed outside of the building by 

means of a special pipe connected with the connection ring 

located on top of the hood. 

 

 CAUTION

!  

The exhausting pipe is not supplied and must be purchased 

apart. 

Diameter of the exhausting pipe must be equal to that of the 

connection ring. 

 

 

 CAUTION

 

If the hood is supplied with active charcoal filter, then it must 

be removed. 

Connect the hood and discharge holes on the walls with a 

diameter equivalent to the air outlet (connection flange). 

Using the tubes and discharge holes on walls with smaller 

dimensions will cause a diminution of the suction performance 

and a drastic increase in noise. 

Any responsibility in the matter is therefore declined.  

Use a duct of the minimum indispensable length. 

Use a duct with as few elbows as possible (maximum 

elbow angle: 90°). 

Avoid drastic changes in the duct cross-section. 

 

Mounting 

Before beginning installation: 

 

•  Check that the product purchased is of a suitable size for 

the chosen installation area. 

•  Remove the charcoal (*) filter/s if supplied (see also 

relative paragraph). This/these is/are to be mounted only 

if you want lo use the hood in the filtering version. 

•  Check (for transport reasons) that there is no other 

supplied material inside the hood (e.g. packets with 

screws (*), guarantees (*), etc.), eventually removing 

them and keeping them. 

Expansion wall plugs are provided to secure the hood to most 

types of walls/ceilings. However, a qualified technician must 

verify suitability of the materials in accordance with the type of 

wall/ceiling. The wall/ceiling must be strong enough to take 

the weight of the hood.  

Do not tile, grout or silicone this appliance to the wall. 

Surface mounting only. 

 

 
 
 