background image

 

You will notice a loss in capturing the fumes If the hood is 
positioned at a distance greater than that recommended. 

 

  Electrical connection 

The mains power supply must correspond to the rating 
indicated on the plate situated inside the hood. If provided with 
a plug connect the hood to a socket in compliance with current 
regulations and positioned in an accessible area. If it not fitted 
with a plug (direct mains connection) or if the plug is not 
located in an accessible area apply a double pole switch in 
accordance with standards which assures the complete 
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation 
instructions. 

Warning! 

Before re-connecting the hood circuit to the mains 

supply and checking the efficient function, always check that 
the mains cable is correctly assembled. 

Warning! 

Power cable replacement must be undertaken  by 

the authorised service assistance centre or similar qualified 
person. 

 

Mounting 

Before beginning installation: 

 

• 

Check that the product purchased is of a suitable size for 
the chosen installation area. 

•  To facilitate installation, remove the fat filters and the 

other parts allowed and described here, dismantle and 
mount it. 

 

To remove see also the relative paragraphs. 

• 

Remove the active carbon (*) filter/s if supplied (see also 
relative paragraph). This/these is/are to be mounted only 
if you want lo use the hood in the filtering version. 

•  Check (for transport reasons) that there is no other 

supplied material inside the hood (e.g. packets with 
screws (*), guarantees (*), etc.), eventually removing 
them and keeping them. 

• 

If possible, disconnect and move freestanding or slide-in 
range from cabinet opening to provide easier access to 
rear wall/ceiling. Otherwise put a thick, protective 
covering over countertop, cooktop or range to protect 
from damage and debris. Select a flat surface for 
assembling the unit. Cover that surface with a protective 
covering and place all canopy hood parts and hardware 
in it. 

• 

In addition check whether near the installation area of the 
hood (in the area accessible also with the hood mounted) 
an electric socket is available and it is possible to 
connect a fumes discharge device to the outside (only 
suction version).  

•  Carry out all the masonry work necessary (e.g. 

installation of an electric socket and/or a hole for the 
passage of the discharge tube). 

Expansion wall plugs are provided to secure the hood to most 
types of walls/ceilings. However, a qualified technician must 
verify suitability of the materials in accordance with the type of 
wall/ceiling. The wall/ceiling must be strong enough to take 
the weight of the hood. 

Do not tile, grout or silicone this 

appliance to the wall. Surface mounting only. 

Only for some models  

An aesthetic flue can be purchased as an optional accessory. 
Check with the authorized dealer whether the model in your 
possession envisages this possibility.  
We advise installing the hood after having purchased the flue 
to check with certainty the most suitable installation. 
  

Fig. 5 

• 

Apply three adhesive strips 

to the back of the hood.

 

  If necessary (in the case of walls not perfectly 

perpendicular or in the presence of walls partly covered 
with tiles) apply two 

D

 spacers in correspondence with 

the definitive fixing holes (click fixing). 

• 

Trace a centre line on the wall to facilitate the montage 

(1)

, position the hole template so that the middle line 

printed on it corresponds to the centre line previously 
drawn and that the lower side of the grill corresponds to 
the lower part of the hood once mounted 

(2)

• 

Make two holes with the 8 mm Ø drill and fix the support 
bracket with two dowels and wall screws

 (3)

•   Open the steam screen and remove the grease filter (see 

relative paragraph).  

•   Hang up the hood 

(4)

, adjusting its position 

(5-6)

 and 

from the inner part of the hood mark two points for the 
definitive fixing 

(7)

. Remove the hood and make two 8 

mm Ø holes 

(8)

, insert two wall dowels, hang the hood up 

again and fix it definitively with two screws 

(9)

• Connect 

the 

electricity 

(10)

, but leave the hood 

disconnected from the general electric panel of the 
house.  

•   If the hood is to be used in the suction version, install the 

flange supplied in the kit on the exit hole of the hood 
(

11A 

- suction version – also install a fumes discharge 

tube of suitable dimensions) instead of the deflector (

11F 

– filtering version

).   

•   Mount the grease filter and close the steam screen. 
 

Attention!

 If the hood is to be used in the suction 

version, remove, if supplied with the kit, the carbon filter 
and the fixing rods (on the back of the grease filter – see 
relative paragraph).  

 

If the hood is to be used in the filtering version, check 
that the carbon filter is already mounted on the back of 
the grease filter or, in its absence, purchase it and install 
it.  

•  Connect the hood to the general electric panel, wait for 

about 15 seconds to allow the hood to calibrate the 
control panel (the leds of the controls flash)  and check 
the functioning. 

 