EN
10
User Manual
1
1.
Push Button
2.
Security Lock
2
BATTERy BOx ExCHANGE
• Place the Ranger Quadra pack on a flat, dry
and clean surface.
• Simultaneously press the central security
lock down before pressing on the outer
releases to separate the Battery Box.
• Place the new, charged Li-Ion Battery Box
on a clean surface.
• Place the Ranger Quadra housing over the
Battery Box.
• Press smoothly down on the Ranger Quadra
pack until you hear two clicks (left/right)
activating the locking mechanism.
• Check, that the Battery Box is well
connectedon both sides of the unit.
TROUBLESHOOTING
The Battery Box offers two protection modes.
1. Safety Mode which will deactivate the Battery Box to avoid damages
2. Protect Failure Mode, which will deactivate the Battery Box to avoid a
danger for the user. The Battery Box cannot be recovered from this mode.
SAfETy MODE
The Safety Mode activates..
• If there is a short cut on the output contacts.
• Over voltage whilst charging, or if the temperature is over +45°C whilst
charging.
• Over current during discharging or if the temperature is over +65°C during
discharge.
• Once the Battery Box “Safety Mode” is active, the Battery Box can be
reactivated:
• Remove the Battery Box from the unit to perform a reset of the internal
protection circuit and reattach the Battery Box to the unit again after a few
seconds.
• If the Safety Mode was activated by overheating the Battery Box, please
wait until the unit cooled down and the temperature is below +45°C.
Summary of Contents for Ranger Quadra EL-19295
Page 74: ......