MODULES EL60/IS - INSTRUCTION 

2012 

16 

 

13.

 

INSTALLATION 

THROUGH 
PHOTOGRAPHIC 
DEMONSTRATION 

 
 
 
 

 
 
 
 

 
 
 
 
Industrial roof framework with 
insulation panel  
 
 
 
 
 
 
 
 
 

 
 
 
 
 
Transpiring membrane 
under tile applying 

 

 
 
 
 
 

 

Summary of Contents for EL60/IS

Page 1: ...2012 www elitalspa com Rev 02 10 2012 EL60 IS PV MODULES KIT SETUP INSTRUCTIONS EL ITAL S p A Z I Pianodardine 83100 Avellino ITALIA Tel 39 0825 621 435 Fax 39 0825 621 480 www elitalspa com ...

Page 2: ... perimeter which joined spliced to each other in an installation of adjacent photovoltaic modules of the same type guarantees the impermeability of the surface without the use of additional components The fins are multiple and being overlapped to each other in order to create a continuous barrier which does not allow the infiltration of water droplets in the lower part of the photovoltaic surface ...

Page 3: ...www elitalspa com MODULES EL60 IS INSTRUCTION 2012 3 KIT 1 X MODULE EL60 IS with Capillary Comb frame 3 X CLAMPS drilled and V shaped 6 X MOUNTING SCREWS FOR PROFILE Auto Drilling and Threading screws ...

Page 4: ...d Photovoltaic Area 7 5 EL60 IS Modules Positioning with Capillary Comb frame 9 6 Setup with metallic or wooden profiles 11 7 Modules Installation Sequence 12 8 Preliminary Operations for rooftop building 12 9 Exclusion of liability 14 10 PV modules disposal 14 11 Setup Tooling 14 12 Component Overview 16 13 Photographic installation sequence 16 14 Installation Examples 19 ...

Page 5: ...on Professional static check is required When working on the roof follow the appropriate safety precautions For heights over 2 meters required safety harnesses Protect the area below the installation site from falling objects NOTES Follow the indications about CAPILLARY COMB system quoted in the following pages The manufacturer can not be sure that these instructions are observed Improper installa...

Page 6: ...Y COMB can be integrated into essentially any roof or mounted on any roof that it is at the recommended minimum of 10 Due to extreme weather conditions condensation can create and moisture can penetrate the soffit of the modules It is absolutely necessary to apply a breathable underlay membrane or vapor barrier Before installing the PV system must be executed a review of the suitability of the roo...

Page 7: ...CTION 2012 7 4 Module Dimensions and Photovoltaic Area Frame Dimension Module External Dimensions EL60 IS equipe with CAPILLARY COMB frame A L1 69mm B L2 69mm Adjacent EL60 IS Modules Overlapping with CAPILLARY COMB frame A 1716 mm B 1060 mm ...

Page 8: ...www elitalspa com MODULES EL60 IS INSTRUCTION 2012 8 Adjacent EL60 IS Modules recommended distance with CAPILLARY COMB frame A 28mm B 28 mm A 28mm A 28mm B 28 mm B 28 mm ...

Page 9: ...60 IS Modules Positioning with Capillary Comb frame Solution A Modules with long side parallel to roof top edge LINEA DI COLMO Solution B Modules with short side parallel to roof top edge LINEA DI COLMO ROOF TOP EDGE ROOF TOP EDGE ROOF TOP EDGE ROOF TOP EDGE ...

Page 10: ... 10 Solution C Modules having two different leanings on the same surface LINEA DI COLMO Recommended Tilt Angle For tilt angles below the minimum recommended limit 10 it is suggested to get in contact with our tecnical staff ROOF TOP EDGE ROOF TOP EDGE ...

Page 11: ...e always installed in the direction of the roof slope gutter and must be installed with a distance of 50 mm minimum in order to allow a proper aeration of the photovoltaic surface Modules having the long side parallel to roof top edge max 250mm max 250mm Modules having the short side parallel to roof top edge max 250mm max 250mm ...

Page 12: ...ons for rooftop building The rooftop setup is charged to the customer and must be preset or renovated following the rules of an entitled designer taking care of all the static as well as thermal parameters depending on the setup place gegraphic position a Rooftop structure residential industrial agricultural ROOF TOP EDGE ...

Page 13: ...rrier placed below tiles c posizioning metallic or wooden profiles Metallic profiles wooden profiles must be positioned following strictly the slope this is done to ensure a proper setup and an adequate photovoltaic surface aeration d EL60 IS modules positioning with Capillary Comb frame ...

Page 14: ... authorized and trained to install such a system It s strictly forbidden to install photovoltaic plants by personnels not properly trained and skilled or without the required knowledge 10 PV modules disposal EL ITAL S p a IS MEMBER OF PV CYCLE FOR THE DISPOSAL OF THE PV MODULES UPON THEIR END OF OPERATION LIFE CYCLE 11 Setup tooling For a proper installaation few tools are required as descrive in ...

Page 15: ... 2012 15 12 Overview components PV Module EL60 IS with CAPILLARY COMB frame FASTEN BRACKETS MODULE n 2 brackets per module for the other modules n 4 brackets per module for the first low line of the pv surface FASTEN BRACKET SCREW n 2 per bracket ...

Page 16: ...www elitalspa com MODULES EL60 IS INSTRUCTION 2012 16 13 INSTALLATION THROUGH PHOTOGRAPHIC DEMONSTRATION Industrial roof framework with insulation panel Transpiring membrane under tile applying ...

Page 17: ...www elitalspa com MODULES EL60 IS INSTRUCTION 2012 17 Placement of PV fastening outline PV fastening on underlying outlines Detail of fitted and fasten bracket ...

Page 18: ...www elitalspa com MODULES EL60 IS INSTRUCTION 2012 18 PV array during assembly fetch PV surface air shaft Plumbing connection ...

Page 19: ...www elitalspa com MODULES EL60 IS INSTRUCTION 2012 19 14 Installation Examples ...

Page 20: ...www elitalspa com MODULES EL60 IS INSTRUCTION 2012 20 ...