lifting them at the ends. As the modules are coupled to each other, when drawn from, not inclining
them, otherwise one runs the risk of deforming the fins of the frames.
Switching on roof
The modules EL60/IS with CAPILLARY COMB frame look like as standard modules, can be handled with
ease on the roof and can be placed on the roof structure making sure the deformation of the fins. It
is important to pay attention on the placement of the modules with sharp corners on roof coverings
because they may be damaged.
Disposal of packaging
Separating and transporting the packaging materials to a recycling center.
Physical removal
It is suggested an immediate check of the modules delivered as well as of its packaging in order to
value any shipping damages. If damage is discovered, make a comprehensive note on the bill of
parcel and document it with photographs.Don’t forget driver’s countersignature.
3.
The requirements that must be the roof of the building
The photovoltaic roof-integrated with the system CAPILLARY COMB can be integrated into
essentially any roof or mounted on any roof that it is at the recommended minimum of
10°. Due to extreme weather conditions condensation can create and moisture can
penetrate the soffit of the modules.
It is absolutely necessary to apply a breathable underlay membrane or vapor barrier!
Before installing the PV system must be executed a review of the suitability of the roof. In
the case of steep slopes of the roof surfaces, these must be leveled.
If the PV system is installed correctly, the roof and photovoltaic modules are well
ventilated and waterproof.
The impermeability to rain is possible first of all thanks to the multiple fins surmounted
one another, creating a continuous barrier which does not allow the infiltration of water
in the lower part of the photovoltaic surface composed of these modules but ensure the
outflow into the lower end of the photovoltaics surface.
The connection to the roof, side, top and bottom is made with the corrugated connection
that must be designed specifically for each individual roof and suitably cutlery to obtain
also in this case a photovoltaic surface impervious to rain and aesthetically valid.
For roof pitches from 10 ° to 20 ° pay attention to the pose of the modules and flashings
fitting.