HOW TO CONNECT POWER (120V)
8
120V FIELD WIRING
COMPARTMENT
USE (U.L. LISTED) CONDUIT FOR
SUPPLYING POWER TO THE UNIT
USE PROPER
WIRE NUTS
DO NOT
DRILL
ADJUSTING GATE TRAVELING DISTANCE
BEFORE ADJUSTING, DO THE FOLLOWING:
1 – Shut off the power.
2 – Push the silver plate inward. Roll the green colored nut to the direction desired.
3 – Place the plate back in the notch.
4 – Turn the machine off.
5 – If you need more adjusting - repeat the process.
*Each notch indicates an estimated 1” of gate traveling distance.
BLACK =
115VAC
WHITE =
NEUTRAL
GREEN =
GROUND
SUGGESTION:
Once you
are through wiring hook-
ups, you may want to seal
all open holes with silicon
or another substance.
WIRE GAUGE REQUIREMENT FOR 115VAC POWER SUPPLY: 1/2 HP & DUAL MOTOR ONLY
CAUTION: ELITE ACCESS SYSTEMS, INC. IS NOT RESPONSIBLE FOR CONFLICTS BETWEEN THE INFORMATION LISTED IN THE ABOVE CHART AND THE
REQUIREMENTS OF YOUR LOCAL BUILDING CODES. THE INFORMATION IS FOR SUGGESTED USE ONLY. CHECK YOUR LOCAL CODES BEFORE INSTALLATION.
16 GAUGE
14 GAUGE
12 GAUGE
10 GAUGE
8 GAUGE
4 GAUGE
150 FEET
250 FEET
400 FEET
650 FEET
1000 FEET
2200 FEET