29
Power Back-Up
E M E R G E N C Y R E L E A S E
Standard
Cover
Manual
Crank
Allen wrench size is 5/16"
1.
Turn the power OFF!
2. Make sure the crank tool fits the crank input, as shown above: Turn the crank to open the gate.
To speed up the process you may use a wireless power drill (6”/sec).
Option 1 :
Model #
CP-17
The chain is held in place by a spring loaded pin.
Turn the power OFF
to the gate operator
and unlock the fire box.
Pull firmly
on the “T”
Handle to
release
the chain.
Option 2 :
Model #
DC-1000U-SL
OPTION A:
In case of power failure the gate opens
automatically one time and stays open.
when power is restored the operator
returns to normal condition.
OPTION B:
In case of power failure the gate will not
open automatically until activated by a
key switch or push button. Maintain con-
tact with the switch or push button until
gate is completely open.
FOR MORE DETAILS