15
ELT-KLCD EliteSuite Installation Manual
Reader Pre-Alarm Timer (Menu 1, 4)
The Reader Pre-Alarm Timer is programmable from 0 to 255 seconds
(Default 30 Seconds). This is only used when the Reader Slave
Network is enabled.
The cursor will flash on the digit you are currently modifying,
entering a number or pressing the [RIGHT] or [LEFT] arrows will
move the cursor to another digit.
The minimum Pre-Alarm Time is 5 seconds, any number lower than 5
seconds entered will be automatically increased to 5 seconds to
ensure correct reader operation.
Reader Left Open Timer (Menu 1, 5)
The Reader Left Open Timer is programmable from 0 to 255 seconds
(Default 45 Seconds). This is only used when the Reader Slave
Network is enabled.
The cursor will flash on the digit you are currently modifying,
entering a number or pressing the [RIGHT] or [LEFT] arrows will
move the cursor to another digit.
The minimum Left Open Time is 5 seconds, any number lower than 5
seconds entered will be automatically increased to 5 seconds to
ensure correct reader operation.
Reader Left Open
time: 045 secs
Reader Pre-Alarm
time: 030 secs