Page 21 of 130
Doc No.
:
T202001006
1. Remove the mains input cable from the back of the control box to ensure that the robot is
completely powered off. Take necessary precautions to prevent other persons from re-energizing the
system during the repair period. When it is powered off, re-check the system to ensure the outage.
2. Please check the earth connection before re-starting the system.
3. Please comply with the electrostatic discharge (ESD) regulations when disassembling the
robot arm or the control box.
4. Avoid disassembling the power supply system of the control box. The high voltage can be
remained inside the power supply system for several hours when the control box is switched off.
5. Prevent water or dust from entering into the robot arm or the control box.
Cautions:
1. Replace the parts trapped in failure with new parts with the identical part number or the
corresponding parts approved by Suzhou Elite Robot Co., Ltd.
2. Reactivate all prohibited safety measures immediately upon completion of the work.
3. Record all maintenance operations in written form and save these records in the relevant
technical documents of the whole robot system.
4. The control box does not have a part that the
end-user
can repair by
himself
. If maintenance
or repair services are needed, please contact with the dealer or Suzhou Elite Robot Co., Ltd.
3.2 Disposal
The ELITE robot must be disposed in accordance with the applicable national laws and
regulations and the national standards.
3.3 Maintenance
The safety functions of the robot must be tested at least once per year, as to ensure that the
functions are correct.