background image

OVERLOAD

POWER

BATTERY LOW

OPEN RELAY

CLOSE RELAY

TIMER

UP

ON

OFF

60

0

PW

CENTRAL CONTROL

SYSTEM ON

DC OPERATOR v 5M

MADE IN USA

ALARM

SENSOR

REVERSE

SENSOR

HEAVY

GATE

FIRE
DEPT

STRIKE

OPEN

SAFETY

LOOP

EXIT
LOOP

RADIO
REC

CHARGING

POWER

BOARD
POWER

CHECK

FUSE

J2

CHARGE OK

CHARGE OK

OVERLOAD

POWER

BATTERY LOW

OPEN RELAY

CLOSE RELAY

TIMER

UP

ON

W1

OFF

OPEN TO RIGHT

60

0

PW

CENTRAL CONTROL

SYSTEM ON

DC OPERATOR v 5M

MADE IN USA

ALARM

SENSOR

REVERSE

SENSOR

HEAVY

GATE

FIRE
DEPT

STRIKE

OPEN

SAFETY

LOOP

EXIT
LOOP

RADIO
REC

CHARGING

POWER

BOARD
POWER

CHECK

FUSE

J2

CHARGE OK

S T E P   B Y   S T E P   I N S T A L L A T I O N

Use Elite's optional 18 VAC plug-in transformer (Elite Part # 

A POW-1

). Hook up the 

transformer to 115 VAC. Use two, low voltage, 14 gauge / 300watt direct burial, landscape 
lighting cables. Hook these wires to the two yellow wires from the control board to the 
plug-in transformer.

STEP 5: DC Power Supply Connection

18 VAC Plug-in Transformer

14 Gauge Wires

Maximum Wire Length 

should not exceed 

1000 ft

.

Polarity Does Not Matter

2

1

3

5

6

8

10

7

9

4

Yellow Wires #2, #4

Do Not

 use solar panel and plug-in 

transformer at the same time.

To 
115 VAC

CAUTION

Beep!

After the plug-in transformer has been connected to the power source, connect the battery 
cable plug to the limit/motor harness plug. You will immediately hear a beep for a few 
seconds. After the beep, check the “

Charge OK

” LED......

Limit/Motor Harness

......it must be 

ON

.

Summary of Contents for Robo Slide

Page 1: ...ROBO SLIDE Residential Gate Operator Installation instructions and manual book for architects general contractors and dealers Copyright 2000 by Elite Access Systems Inc www eliteaccess com Click on the desired topic in the Bookmarks column or Table of Contents to select page ...

Page 2: ...ators with Timer Master and Slave Operators without Timer Control Board Functions LED Descriptions Troubleshooting How to Reset Breaker Switch How to Check Fuses Gate will not close Gate will not open If you hear a BEEP sound Robo Slide Parts List Robo Slide Parts 2 3 4 5 5 6 6 7 8 9 10 11 11 12 13 14 15 16 17 18 19 19 20 20 21 21 22 PLEASE DO NOT TOUCH ME UNLESS YOU ARE AN AUTHORIZED SERVICE TECH...

Page 3: ...s in Gate s Path 1 4 Clearance from Top of Gate 5 A physical stop MUST be installed on the gate prior to installation of the gate operator This will assure that the gate does not derail while in motion CAUTION Gate in Fully Opened Position Gate Clearances IMPORTANT Because gate coasting distance varies with temperature Elite DOES NOT recommend the installation of a catch post This could cause the ...

Page 4: ...Never Let Pedestrians Cross the Path of a Moving Gate Owners Must Never Mount Any Gate Operating Devices Accessible In Between the Gate and the Wall Owners Must Never Mount Any Gate Operating Devices Accessible Through the Gate CAUTION CAUTION CAUTION ...

Page 5: ...N Robo Slide Specifications Gate Speed 11 inch per second Maximum Gate Length 20 feet Maximum Gate Weight 800 pounds Maximum Cycles 70 cycles per day with Elite s Plug In Transformer Solar power cycles per day varies Contact Elite for more Information Battery back up cycles 50 cycles total AC Power Supply 18 VAC 2 0 Amp Plug In Transformer Elite Part A POW 1 AC Power Supply Wire 14 gauge or greate...

Page 6: ...8 VAC 2 0 Amp 4 Do not install as a rear mount installation 5 Use only 14 gauge or greater landscape lighting cable rated for direct burial and 300 watts Robo Slide For Single Home Applications STEP 1 Getting Started This gate operator is designed for single home application or for limited commercial applications An example of a commercial application would be a factory facility with limited cycle...

Page 7: ... gate operator bolt down the operator to the concrete bed Make certain that the concrete bed is solid 6 Concrete Reinforced Recommended Above Ground Power Supply Line 20 20 15 10 8 OVERLOAD POWER CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY TIMER UP ON W1 OFF OPEN TO RIGHT 60 0 PW CENTRAL CONTROL SYSTEM ON DC OPERATOR v 5M MADE IN USA ALARM SENSOR REVERSE SENSOR HEAVY GATE FIRE DEPT STRIKE OPEN SA...

Page 8: ...if the gate opens to the right and closes to the left from the inside of the property OVERLOAD POWER CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY TIMER UP ON W1 OFF OPEN TO RIGHT Socket 1 Socket 2 60 0 PW CENTRAL CONTROL SYSTEM ON DC OPERATOR v 5M MADE IN USA ALARM SENSOR REVERSE SENSOR HEAVY GATE FIRE DEPT STRIKE OPEN SAFETY LOOP EXIT LOOP RADIO REC CHARGING POWER BOARD POWER CHECK FUSE J2 OUT IN...

Page 9: ...A T I O N Use Elite s optional 18 VAC plug in transformer Elite Part A POW 1 Hook up the transformer to 115 VAC Use two low voltage 14 gauge 300watt direct burial landscape lighting cables Hook these wires to the two yellow wires from the control board to the plug in transformer STEP 5 DC Power Supply Connection 18 VAC Plug in Transformer 14 Gauge Wires Maximum Wire Length should not exceed 1000 f...

Page 10: ... Y S T E P I N S T A L L A T I O N STEP 6 Optional Solar Panel Connection Energizing Robo Slide with solar power only needs the radio receiver to operate the gate The only recommended external devices other than radio receivers are dry contact command devices which do not consume any current like key switches Using other devices that consume high current such as telephone access magnetic locks or ...

Page 11: ...nal 10 Red Wire 4 7 8 0 HELP 9 1 2 3 5 6 Photo Electric Eye The radio receiver must be 12 VDC only Elite Part A 1099 12V If you want to use safety or exit loops you must use 12 VDC loop detectors only Elite Part A 23 The hook ups for the radio receiver are as follows Strike open wires go to 8 and 9 on terminal Power supply goes to terminal 10 positive and terminal 8 negative Connections for other ...

Page 12: ...e timer switch should be put in the ON position If you want to use the push open or push close command the timer should be switched to the OFF position Limit Switches Each notch of the nut indicates an estimated 1 inch of gate travel OVERLOAD POWER BATTERY LOW OPEN RELAY CLOSE RELAY TIMER UP ON W1 OFF OPEN TO RIGHT 60 0 PW CENTRAL CONTROL SYSTEM ON DC OPERATOR v 5M MADE IN USA ALARM SENSOR REVERSE...

Page 13: ...L A T I O N STEP 10 Two Way Adjustable Reversing Sensor OVERLOAD POWER BATTERY LOW OPEN RELAY CLOSE RELAY TIMER UP ON W1 OFF OPEN TO RIGHT 60 0 PW CENTRAL CONTROL SYSTEM ON DC OPERATOR v 5M MADE IN USA ALARM SENSOR REVERSE SENSOR HEAVY GATE FIRE DEPT STRIKE OPEN SAFETY LOOP EXIT LOOP RADIO REC CHARGING POWER BOARD POWER CHECK FUSE J2 CHARGE OK SYSTEM ON ALARM SENSOR REVERSE SENSOR HEAVY GATE NOW Y...

Page 14: ... the J2 slot on the top of the control board Below lists the function of each pin Open Switch Stop Switch Cut W1 Jumper at Bottom of Board Timer Close Output from Master to Slave Timer Input from Slave to Master Close Command Vandalism Alarm Output Not Burglar Alarm 12 VDC Emergency Open Direct Command from Battery to Motor Emergency Close Direct Command from Battery to Motor Magnetic Lock Dry Con...

Page 15: ...ug connections as shown above 2 Turn timers on BOTH control boards to the ON position 3 Use MASTER timer ONLY for the auto close time adjustment 0 to 60 sec 4 Turn the SLAVE timer adjustment all the way Counterclockwise Slave J2 Plug Master Pin 1 to Slave Pin 1 Master Pin 5 to Slave Pin 7 Master Pin 6 to Slave Pin 8 Master Pin 2 to Slave Pin 2 Caution 18 VAC plug in transformer per gate operator r...

Page 16: ... 14 12 10 6 8 4 2 15 13 11 9 5 7 3 2 Low Voltage Wires Connect Gate Operators Together Master J2 Plug 1 Make master slave J2 plug connections as shown above 2 Turn timers on BOTH control boards to the OFF position Slave J2 Plug Master Pin 1 to Slave Pin 1 Master Pin 2 to Slave Pin 2 Caution 18 VAC plug in transformer per gate operator required 1 Master Timer OFF Master Slave Slave Timer OFF TIMER ...

Page 17: ... 6 Close Relay LED 7 System on Reversing sensor and Alarm sensor 8 Alarm sensor LED 9 Reversing sensor LED Rebounder 10 Central control LED 11 Fire department or key switch LED 12 Strike open LED 13 Safety loop or photocell LED 14 Exit loop LED 15 Radio receiver LED 16 Timer power LED 17 Timer Up indicator 18 J2 alternate optional output 19 Movement direction sockets 20 Replace fuse indicator 21 S...

Page 18: ...ge is over minimum required limit Gate weight and condition are OK System is OK Open relay is energized Flashing LED Battery is less than required limit needs to be recharged Power source OK and board power fuse OK Transformer or solar OK and charging power fuse OK 1 Excess usage 2 Bad charging system 3 Under rate solar panel 4 Bad battery 5 Bad battery connection 1 Hearing beep sound means overlo...

Page 19: ... Fire Department 1 2 Strike Open 3 4 Safety Loop 5 6 Exit Loop 7 8 Radio Receiver 8 9 12 Strike Open Receiving signal at terminal block 3 4 Not receiving signal at terminal block 3 4 13 Safety Loop Receiving signal at terminal block 5 6 Not receiving signal at terminal block 5 6 14 Exit Loop Receiving signal at terminal block 7 8 Not receiving signal at terminal block 7 8 15 Radio Rec Receiving si...

Page 20: ...E S H O O T I N G If all electronic sensors fail or are not adjusted properly due to heavy gates off track gate or obstructed gate path the breaker will kick out Reset the breaker by pressing the reset button located on the bottom left corner of the control board How to Reset the Breaker How to Check the Fuses CAUTION CAUTION Always disconnect the battery before resetting the breaker or injury cou...

Page 21: ...io receiver has malfunctioned in the ON position 0 PW CENTRAL CONTROL DC OPERATOR v 5M MADE IN USA FIRE DEPT STRIKE OPEN SAFETY LOOP EXIT LOOP RADIO REC The Gate Will Not Open Symptom The radio receiver LED on the control board remains OFF when using the remote control Possible Solutions Dead battery in the remote control Remote control code switches are different from radio receiver code switches...

Page 22: ... Nut Q131 Limit Switch Drive Sprocket Q132 Limit Switch Sprocket Q133 Drive Sprocket Q135 Limit Switch Bolt Shaft Q137 Limit Switch Box Q156 1 2 Inch Collar Q162 Fuse Q180 1 inch Diameter Coupling Q203 Option Board with Harness Q206 Control Board Q211 Limit Motor Harness Q212 Gear Reducer 40 30 1 Q218 Terminal Harness Q241 Cover Polyethylene Plastic If you hear a BEEP sound the gate is too heavy I...

Page 23: ...REC CHARGING POWER BOARD POWER CHECK FUSE J2 Q004 Q003 Q006 Q162 Q203 Q206 Q211 Q206 Q218 Battery Harness Q204 Conversion Kit Q134 Q133 Q132 Q131 Q218 Q211 Q212 Q180 Q123 Q129 Q124 A BT 12 A H 110 41 A H 113 A H 125 A H 111 40 Q029 Q137 Q135 Q156 Q032 Q101 OVERLOAD POWER CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY TIMER UP ON W1 OFF OPEN TO RIGHT 60 0 PW CENTRAL CONTROL SYSTEM ON DC OPERATOR v 5M...

Reviews: