background image

PAR.

DESCRIPTION

RANGE

DEFAULT

VALUE

LEVEL

U.M.

SEt

Set point with range falling between the minimum 
LSE set point and the maximum HSE set point. The
set point value is in the 

machine status menu 

menu

LSE...HSE

0.0

°C/°F

diF

When the compressor stops when it reaches the
set point value, it restarts at a value corresponding
to the set point plus the value of the differential It

must not be 0

0.1...30.0

2.0

1-2

°C/°F

HSE

Maximum set point value

LSE...302

50.0

1-2

°C/°F

LSE

Minimum set point value

-58.0...HSE

-50.0

1-2

°C/°F

OSP

Offset point. Value to be added to set point if
reduced set point is activated Economy function).

-30.0...30.0

0

2

°C/°F

Cit

Minimum compressor ON time. Minimum time for 
activating a compressor before deacti vation Not
active if=0

0...250

0

2

min

CAt

Maximum compressor ON time. Maximum time for
activating a compressor before deacti vation Not
active if=0

0...250

0

2

min

Ont   (1)

Compressor activation time if probe is faulty. If set
to 1 with OFt=0 the compressor always remains on
whereas if OFt>0 it operates in duty cycle mode
(see 

Duty Cycle

diagram)

0...250

0

1-2

min

OFt   (1)

Compressor shut-down time if probe is faulty. If set
to 1 with Ont=0 the compressor always remains off
whereas if OFt>0 it operates in duty cycle mode
(see 

Duty Cycle

diagram)

0...250

1

1-2

min

dOn

Delay in activating compressor relay after start-up

0...250

0

1-2

sec

dOF

Delay after shut-down; between compressor relay
shut-down and subsequentstart-up the specified
time must elapse.

0...250

0

1-2

min

dbi

Delay between switch-ons; the specified time must
elapse between two subsequent switch-ons

0...250

0

1-2

min

OdO 

Delay in activating outputs after start-up of instru-
ment or after a power failure. 
Not active if=0

0...250

0

1-2

min

dty

Type of defrost. 
0 = electrical defrosting; 
1 = cycle reversing defrosting (hot gas); 
2 = Free mode defrosting (compressor disabled).

0/1/2

0

1-2

num

dit

Period of time elapsing between the start of two
defrosts 0=function disabled

0...250

6h

1-2

hours/min/sec

dt1

Unit of measurement for defrost

times (par. dit)

0=”dit” expressed in hours 
1=”dit” expressed in minutes 
2=”dit” expressed in seconds

0/1/2

0

2

num

NOTE:   At level 1 the folders will only display all the level 1 parameters. At level 2 the folders will only display all the level

2 parameters. The symbol 1-2 indicates the parameters that are displayed at both menu levels

Defrosting controller

-dEF label

Compressor controller

-CP label

dt2

Unit of measurement for duration of defrosting
(dEt parameter) 
0= “dEt” parameter expressed in hours 
1= “dEt” parameter expressed in minutes 
2= “dEt” parameter expressed in seconds

0/1/2

1

2

num

dCt

Selection of defrosting time count mode. 
0=compressor operating hours DIGIFROST®
method). Defrosting active only if compressor is
on. 
1 = device operating hours; defrost counting is 
always active when the machine is on 
2=compressor stop Each time the compressor 
stops a defrosting cycle 
defrost cycle is performed according to par. dtY 

3=disabled

0/1/2/3

1

1-2

flag

dOH 

Delay between start of first defrosting operation
and start-up of instrument.

0...59

0

1-2

min

dEt

Defrosting time-out; determines maximum dura-
tion of defrosting.

1...250

30min

1-2

min/sec

EWDR 981 

4/8

Summary of Contents for EWDR 981

Page 1: ... main menu level The set point setting folder is also closed when the time out elapses Alarm on If an alarm condition exists when the Machine Status menu is accessed the ALfolder label appears PARAMETER PROGRAMMING MENU Access the menu by pressing the set button for at least 5 seconds The menu structure enables all parameter folders to be divided into two levels All the level 1 folders can be acce...

Page 2: ...eter OFL Y DIAGNOSTICS PROBE ALARMS When one of the probes is outside the nominal operating range or the probe is open or has shorted an alarm is generated if at least one of these conditions persists for at least 10 seconds If at least one of these 3 alarms is signalled the alarm LED and relay are enabled When activated code E1 appears on the display If several alarms are activated at the same ti...

Page 3: ...ded using an ordinary bipolar cable note that if probes are extended this affects the electromagnetic compatibility EMC of the instrument special care must be used when wiring The TTL serial cable must be kept separate from the power cables EWDR 981 3 8 CONDITIONS OF USE PERMITTED USE For safety reasons the instrument must be installed and used in accordance with the instructions supplied Users mu...

Page 4: ... min dbi Delay between switch ons the specified time must elapse between two subsequent switch ons 0 250 0 1 2 min OdO Delay in activating outputs after start up of instru ment or after a power failure Not active if 0 0 250 0 1 2 min dty Type of defrost 0 electrical defrosting 1 cycle reversing defrosting hot gas 2 Free mode defrosting compressor disabled 0 1 2 0 1 2 num dit Period of time elapsin...

Page 5: ...is regulated by Att below which the alarm is activated 50 0 HAL 50 0 1 2 C F PAO 3 Alarm exclusion time after start up of instrument following a power failure 0 10 0 1 2 hours dAO Alarm exclusion time after defrosting 0 999 0 1 2 min EWDR 981 5 8 OAO High and low temperature alarm delay after disabling digital input door closed 0 10 0 2 hours tdO Time out after alarm signal when digital input is d...

Page 6: ...to temperature displayed that is also used by controllers 0 1 2 2 2 num LdL Minimum value that can be displayed 55 0 140 50 0 2 C F HdL Maximum value that can be displayed 50 0 302 140 0 2 C F ddL display during defrosting 0 displays temperature read by thermostat control probe 1 displays temperature read entering defrost cycle until set point is reached 2 displays dEF label during defrosting unti...

Page 7: ...s set to positive values and the parameter LAL is set to negative values LAL 3 Refers exclusively to high and low temperature alarms 4 when changing from C to F or vice versa the set points differentials etc are NOT converted for example set 10 C becomes set 10 F 5 CAUTION positive or negative values change polarity Positive values active input when contact is closed Negative values active input w...

Page 8: ...NG DIAGRAM TERMINALS 1 2 Probe input 1 room probe 1 4 Probe input 3 display or 2nd evaporator probe 5 6 Digital input 1 5 7 Digital input 2 8 9 Auxiliary output 12Vc 20mA E see par H25 alarm default 13 14 Power supply 230Va A TTL input for Copy Card 20 21 22 N O relay output C see par H21 compressor default 19 22 N C relay output C see par H21 compressor default EWDR 981 1 2 4 5 6 7 8 9 10 11 12 1...

Reviews: