PARAMETER

HC1

dF1

HS1
LS1

dn1

do1

di1

dE1

On1

OF1

LOC

PA1

ndt

CA1

dro

H00 (1) (!)

H10

rEL
tAb

UL

dL

Fr

(1) 

PARAMETER VISIBLE ONLY INTcJ/TcK MODELS. Pt100 Model works only with Pt100 sensor (3 wires) while TcJ and TcK Models work also with Pt100 sensor

selectable by this parameter

* DEFAULT column: for parameters HC1, HS1, LS1, DF1, H00/10 the default depends don the model.
* VALUE column: to be filled manually, with customized settings (if different from the default value).

(!) WARNING!

• If one or more of these parameters highlighted with (!)  are modified, teh controller must be switched off and switched on again to ensure correct operation.
• It is strongly recommended, anyway to switch off and switch on again the controller anytime parameters have been changed to prevent malfunctioning on configuration
and/or ongoing timings

3/4

DESCRIPTION

REGULATOR 1 (folder with “rE1” label)

Heat/Cool Mode. If set to H the generic regulator actuates for hot
operation. If set to C the generic regulator actuates for cold opera-
tion
diFferential. Relay 1 tripping differential. The regulator stops on
reaching the Setpoint value (as indicated by the adjustment
probe), and restarts at temperature value equal to the Setpoint 1
plus (o minus depending on HC1) the value of the differential.

see ON-OFF regulation diagram

Higher SEt. Maximum possible setpoint 1 value.
Lower SEt. Minimum possible setpoint 1 value. 

REGULATOR 1 PROTECTIVE DEVICE (folder with “rE1” label)

Delay time in activating the regulator relay after switch-on of
instrument. 
Delay after switch off. The indicated time must elapse between
switch-off of the regulator relay and the successive switch-on. 
Delay between switch-ons. The indicated time must elapse
between two successive switch-ons of the regulator.
Delay before switch-off. The indicated time must elapse between
switch-off request and the switch-off of  the regulator.
On time (regulator 1). 
Regulator activation time in the event of faulty probe. If set to “1”
with OF1 at “0” the regulator  is always on, while at OF1 >0 it
functions always in duty cycle mode. .

see Duty Cycle Diagram

OFF time (regulator 1). Regulator in disabled state time in the
event of a faulty probe. If set to “1” with On1 at “0” the regulator
is always off, while at On1 >0 it functions always in duty cycle
mode. 

see Duty Cycle Diagram

DISPLAY (folder with “diS” label)

(keyboard) LOCk (set and keys). Keyboard locking. However, you
can enter parameter programming
modify them along with the status of this parameter in order to
allow keyboard locking. y = yes; n = no
PAssword 1. When enabled (value other than 0) it constitutes the
access key for level 1 parameters.
number display type. View with decimal point. y = yes; n = no

PLEASE NOTE: for modelsTcJ/TcK only n value.

CAlibration 1.Calibration 1. Positive or negative temperature value
added to the value read by probe 1, 
display read-out. Select °C or °F for displaying  the temperature
read by the probe. 

PLEASE NOTE: the switch between °C and °F

DO NOT modify setpoint, differential, etc. (for example
set=10°C become 10°F).
CONFIGURATION (folder with “CnF” label)
PLEASE NOTE: PARAMETER VISIBLE ONLY INTcJ/TcK MODELS

Probe type selection: Pt1 for Pt100; JtC: for TcJ; HtC for Tck
delay time in activating the outputs after switch-on WARNING! If
set = 0 it is not active; if set 

0 output will not be activated before

this time 
reLease firmware. Device version: read only parameter.
tAble of parameters. Reserved: read only parameter.

COPY CARD (folder with “Fpr”label)

Up load. Programming parameter transfer from instrument to
Copy Card.
Down load. Programming parameter transfer from Copy Card to
instrument
Format. Erasing all data in the Copy Card.

PLEASE NOTE using “Fr” parameter (copy card formatting)
the data within the copy card will be lost permenently. The
operation cannot be cancelled. After using the copy Card
device the controller must be switch off and switch on again

Tab. 1

Parameter Table

DEFAULT*

H/C*

0 (n.z. models)*

1*

*
*

1

0

0

0

0

1

n

0

n

0

°C

Pt1/JtC/HtC*

0

/
/

/

/

/

RANGE

H/C

0.0...30.0

LS1..HdL
LdL..HS1

0...250

0...250

0...250

0...250

0...250

0...250

n/y

0...250

n/y

-30.0...30.0

°C/°F

Pt1/JtC/HtC

0...250

/
/

/

/

/

VALUE*

U.M.

flag

°C/°F

°C/°F
°C/°F

sec

min

min

sec

min

min

flag

num

flag

°C/°F

flag

num

min

/
/

/

/

/

IC 912 Pt100/TcJ/TcK

Summary of Contents for IC 912 Pt100-TC

Page 1: ...se set then set the desired value using the UP and DOWN keys and confirm with the set key to move to the next parameter PLEASE NOTE It is strongly recommended to switch off and switch on again the con troller anytime parameters have been changed to prevent malfunctioning on configuration and or ongoing timings PASSWORD The password PA1 allows access to level 1 parameters In the standard configura ...

Page 2: ...ference standards on safety It is classified as follows according to its manufacture as an auto matic electronic control device to be incorporated by independent mounting according to its automatic operating fea tures as a 1 B type operated control type as a Class A device in relation to the cat egory and structure of the software UNPERMITTED USE Any other use other than that permitted is de facto...

Page 3: ...or is always on while at OF1 0 it functions always in duty cycle mode see Duty Cycle Diagram OFF time regulator 1 Regulator in disabled state time in the event of a faulty probe If set to 1 with On1 at 0 the regulator is always off while at On1 0 it functions always in duty cycle mode see Duty Cycle Diagram DISPLAY folder with diS label keyboard LOCk set and keys Keyboard locking However you can e...

Page 4: ...relays with 8 3 1 2 hp 250V capability Wiring diagram SP1 SP1 dF1 dF1 Off On HC1 H ON OFF Regulation Diagram OF1 Off On OUT On1 On1 parameters On1 ed OF1 programmed for the duty cycle When the analogue input detects an error condition the code E1 is displayed the regulator is activated as indicated by the On1 and OF1 parameters if pro grammed for the duty cycle Duty Cycle Diagram On1 0 0 0 0 OF1 0...