IC 912 Pt100/TcJ/TcK

4/4

Invensys Controls Italy s.r.l

via dell'Industria, 15 Zona Industriale Paludi
32010 Pieve d'Alpago (BL) ITALY
Tel39 0437 986111
Fac39 0437 989066
Internet http:/www.climate-eu.invensys.com

12/2002 eng
cod. 9IS22093

IC 912 Pt100-TC - 12 V

A

6 7

10 11 12

+

-

1 2 3

IC 912 Pt100-TC - 230 V

A

10 11

+

-

12

6 7

1 2 3

WIRING 

1 - 2

N.O. regulator 1 relay output (OUT1)

1 - 3

N.C. regulator 1 relay output (OUT1)

6 - 7

Power supply 1,5 VA max. (12V version)
Power supply 3 VA max. (230V version)

*10-11-12

Pt100 3 wires input

*11-12 

TcJ/TcK input (11 = +; 12 = -)

A

TTL input for Copy Card

PLEASE NOTE: 

* depending on model
• User Default Settings
• for relay capacities check on the instrument label

In the diagram it is shown relays with 8(3) 1/2 hp 250V 
capability

Wiring diagram

SP1

SP1-dF1

dF1

Off

On

HC1=H

ON-OFF Regulation Diagram

OF1

Off

On

OUT

On1

On1

parameters On1 ed OF1 programmed for
the duty cycle

When the analogue input
detects an error condition: 
• the code E1 is displayed 
• the regulator is activated as
indicated by the "On1)" and
"OF1" parameters if pro-
grammed for the duty cycle

Duty Cycle Diagram

On1

0
0
>0
>0

OF1

0
>0
0
>0

regulator output

OFF
OFF
ON
D.C.

DISCLAIMER

This manual and its contents remain the sole property of Invensys Controls Italy
s.r.l., and shall not be reproduced or distributed without authorization. Although
great care has been exercised in the preparation of this document, Invensys
Controls Italy s.r.l., its employees or its vendors, cannot accept any liability whatso-
ever connected with its use. Invensys Controls Italy s.r.l. reserves the right to make
any changes or improvements without prior notice.

Summary of Contents for IC 912 Pt100-TC

Page 1: ...se set then set the desired value using the UP and DOWN keys and confirm with the set key to move to the next parameter PLEASE NOTE It is strongly recommended to switch off and switch on again the con troller anytime parameters have been changed to prevent malfunctioning on configuration and or ongoing timings PASSWORD The password PA1 allows access to level 1 parameters In the standard configura ...

Page 2: ...ference standards on safety It is classified as follows according to its manufacture as an auto matic electronic control device to be incorporated by independent mounting according to its automatic operating fea tures as a 1 B type operated control type as a Class A device in relation to the cat egory and structure of the software UNPERMITTED USE Any other use other than that permitted is de facto...

Page 3: ...or is always on while at OF1 0 it functions always in duty cycle mode see Duty Cycle Diagram OFF time regulator 1 Regulator in disabled state time in the event of a faulty probe If set to 1 with On1 at 0 the regulator is always off while at On1 0 it functions always in duty cycle mode see Duty Cycle Diagram DISPLAY folder with diS label keyboard LOCk set and keys Keyboard locking However you can e...

Page 4: ...relays with 8 3 1 2 hp 250V capability Wiring diagram SP1 SP1 dF1 dF1 Off On HC1 H ON OFF Regulation Diagram OF1 Off On OUT On1 On1 parameters On1 ed OF1 programmed for the duty cycle When the analogue input detects an error condition the code E1 is displayed the regulator is activated as indicated by the On1 and OF1 parameters if pro grammed for the duty cycle Duty Cycle Diagram On1 0 0 0 0 OF1 0...

Reviews: