M1 Cross Platform Controllers - User Guide
Page 10
Bypassing Zones
(Optional) Manual bypassing of a zone will exclude it from the system for the
immediate arming period. * [see notes below] Once the system is armed,
zone(s) that are bypassed will not be able to activate an alarm. The bypass
will remain in effect until: a) the zone bypass is canceled, or b) the system is
disarmed. The
Bypass
key will be lighted whenever a zone is bypassed.
To bypass a zone:
1.
Press the
Bypass
key.
2.
Enter the number of the zone you wish to bypass.
3.
Press the
Bypass
key again.
4.
The Bypass light will light up if the bypass is accepted. However, if
the zone is non-bypassable an error tone will be heard.
Quick Bypassing of Violated Zones
(Optional) The Quick Bypass feature allows you to bypass all violated zones
with a minimum number of keystrokes. * [see notes below]
To quick bypass any violated zones:
1.
Press the
Bypass
key.
2.
Enter 999
3.
Press the
Bypass
key again.
4.
If the quick bypass is accepted the Bypass light will be illuminated.
However, if any of the zones were non-bypassable an error tone will
be heard.
* Only zones that have been programmed as bypassable can be bypassed.
* Bypassing may additionally require a user code that has been enabled with
the user bypass option.