84-SYSTEM TESTS
Allows Battery Test, LCD Test, & Communicator Test.
Option 1: Battery Test Places the battery under load for 30 seconds. Battery
voltage and system current ** will display. If the voltage falls below 12.2V, a
Low Battery trouble will occur. Replace the battery and repeat test to clear..
Option 2: LCD Test Briefly turns on all the keypad’s display pixels.
Option 3: Communicator Test There are 3 sub-options:
- Silent Test: Sends a communicator test using the first phone number that is
programmed with a test code. The test aborts if no telephone numbers are
programmed with a test code. No noise or tones will be heard.
- Audible Test:
**
Same as Silent Test except the dialing and communicator
tones will be heard over the internal speaker(s) for the Installer’s benefit.
- Monitor (Buttset) mode:
**
This causes the internal speakers to activate
during any subsequent communicator activity. It cancels itself at midnight
or can be manually canceled by pressing the * key three times in a row.
IMPORTANT: NEVER TEST THE COMMUNICATOR WITHOUT FIRST
NOTIFYING THE MONITORING STATION!
85-CONNECT RP REMOTE PROGRAM
Do Not Use except under guidance
of the installation company. There are two options:
Option 1: Pickup on Existing Call The system picks up the phone line and
take over an established voice connection for a quick programming change.
Option 2: Dial out to Remote Computer The system picks up the phone line
and dials the remote computer. It must be set to expect the call.
86-SYSTEM DIAGNOSTICS
This is expressly for use by a service techni-
cian. There are four options:
Option 1: Data Bus Errors Display the device type and any error retries
accumulated since the last power-up.
Option 2: System Voltage/Current Displays the system’s voltage. Displays
approx. current draw from the power supply.
**
Option 3: Zone Voltage Displays the voltage and digital level of a zone,
including the low and high thresholds.
Option 4:Last On Hook Telephone Displays the telephone line voltage during
the last on-hook state.
87-CUSTOM MESSAGE RECORD
** The installer can assign up to 10
custom recordable messages to be used with the telephone voice remote
and/or dialer. Detailed instructions are contained in the installation manual.
Consult your installer for specific instructions on what messages (if any) may
be recorded and for the step by step instructions to record them.
** Not applicable to the M1EZ8