SAMPLE APPLICATIONS AND WIRING DIAGRAMS (Set jumpers as shown)
12/24
Volts
DC
Power
Supply
12/24V
DOOR
STRIKE
DOOR
STRIKE
HOLD
TIMER
+
‐
‐
+
1
+
‐
TGR
JP5
JP1
JP2
JP3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK
‐
960
Delay
Timer
K1
N/O
Pushbutton
Used to extend the release time of an access control device
or to manually activate a door
strike
release device. The
trigger is activated by a contact closure or a N/O pushbutton
and the door strike remains activated (door open) after the
button is released for the delay time set up in the ELK-960.
12/24V
MAGLOCK
MAGLOCK
RELEASE
TIMER
+
‐
2
+
‐
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK
‐
960
Delay
Timer
K1
12/24
Volts
DC
Power
Supply
‐
+
N/O
Pushbutton
Used to extend the release time of an access control device
or to manually activate a door
maglock
release device. The
trigger is activated by a contact closure or a N/O pushbutton
and the door maglock remains released (door open) after the
button is released for the delay time set up in the ELK-960.
12
Volts
DC
Power
Supply
SIREN
DOOR
PROP
ALARM
TIMER
+
‐
‐
+
3
+
‐
TGR
JP5
JP1
JP2
JP3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK
‐
960
Delay
Timer
K1
Delay
is
started
when
the
door
is
opened.
If
the
door
remains
opened
after
the
time
delay
has
expired
the
relay
will
turn
on
and
remain
on
until
the
door
is
closed.
If
the
door
is
closed
before
the
time
delay
expires
the
ELK
‐
960
is
reset
awaiting
another
input
from
the
door
contact.
N/C
CONTACT
ON
DOOR
+ ARMED
OUTPUT
+
TGR
JP5
JP1
JP2
JP3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK-960
Delay Timer
K1
EXIT DELAY
SHUNT TIMER
CLOSED
ZONE
INPUT
CONTROL PANEL
+
12V AUX
N/C
CONTACT ON
EXIT DOOR
Provides an exit delay to an otherwise instant alarm loop.
The ELK-960 is triggered by the control's Armed output.
The door contact is then shunted by the relay contacts.
After the user has exited and the delay time has expired,
the door contact is restored into the loop.
ALARM
CUT
‐
OFF
TIMER
12V
Bell
or
Siren
+
‐
12V
ALARM
OUTPUT
‐
+
CONTROL
PANEL
7
+
‐
TGR
JP5
JP1
JP2
JP3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK
‐
960
Delay
Timer
K1
Useful
for
adding
a
cut
‐
off
timer
to
a
control
panel
that
does
not
have
one.
It
can
also
be
used
to
shorten
the
cut
‐
off
timer
for
a
control
with
no
adjustable
timer.
+
‐
TGR
JP5
JP1
JP2
JP3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK
‐
960
Delay
Timer
K1
120VAC
Supply
Motion
Detector
N/C
COM
120V
LIGHT
AUTOMATIC
LIGHT
CONTROL
4
Hot
Neutral
+
‐
22K
Ohm
Resistor
12
Volts
DC
Power
Supply
‐
+
For
turning
on
an
interior
or
exterior
light
with
a
motion
detector.
When
motion
is
detected,
the
ELK
‐
960
is
triggered
and
the
light
is
turned
on.
The
amount
of
time
the
light
remains
on
after
the
detector
resets
is
adjustable.
Delay
time
will
automatically
restart
each
time
the
motion
detector
activates.
INSTANT
ACTIVATION
OF
ZONE
WITH
DELAYED
RESTORAL
6
+
‐
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK
‐
960
Delay
Timer
K1
N/C
CONTACT
CLOSED
ZONE
CONTROL
PANEL
‐
+
12V
AUX
22K
Ohm
Resistor
When
contact
opens,
relay
is
turned
on
which
causes
instant
zone
violation.
Contact
reclosure
will
cancel
trigger
applied
by
resistor.
Delay
starts
when
contact
closes.
Relay
turns
off
and
zone
restores
after
delay
time
expires.
BELL
OR
LIGHT
FLASHER
12V
LIGHT
or
LED
+
‐
+
‐
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK
‐
960
Delay
Timer
K1
8
12V
ALARM
OUTPUT
‐
+
CONTROL
PANEL
12V
Bell
or
Siren
+
‐
Converts
a
steady
output
to
pulsing,
suitable
for
flashing
a
light
or
pulsing
an
audible
device.
Note:
Alarm
output
must
be
capable
of
supplying
enough
current
to
drive
the
bell
and
light.
+
‐
TGR
JP5
JP1
JP2
JP3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK
‐
960
Delay
Timer
K1
120VAC
Supply
120V
LIGHT
USING
TWO
960'S
TO
DELAY
AND
THEN
TOGGLE
A
RELAY
9
Hot
Neutral
12
Volts
DC
Power
Supply
‐
+
+
‐
TGR
JP5
JP1
JP2
JP3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
ELK
‐
960
Delay
Timer
K1
N/O
SWITCH
#1
#2
Used
for
delaying
a
trigger
then
toggling
a
relay
on/off.
ELK
‐
960
#1
starts
a
time
delay
when
the
N/O
switch
is
closed.
When
960
#1's
time
delay
expires,
960
#2
is
triggered
turning
it's
relay
on
for
the
time
delay
setting
,
then
turning
the
relay
off.
(toggle)
To
sumarize:
fire
trigger
on
#1,
waits,
turns
on
#2's
relay,
waits,
then
turns
relay
off.