M1EZ8 Installation and Programming
Page 29
[Effective w/Firmware 4.3.6]
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
ZN001 02:Type=0
r
0=EOL Supervised
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
ZN001 03:Area=1
r
[Area Name]
Refers to the wiring configuration for zones. Burglar and Keyswitch zones may be set to:
0, 1, 2, 3, & 4. Other non-fire zones may be set to: 0, 1 or 2 only. Fire zones may be
5=EOL Supervised 4-wire detectors, 6=EOL Supervised 2-wire detectors (zone 8 ONLY!)
Enter the area (partition) number that this zone is to be assigned to. A zone can only
reside in one area and fire zones can only reside in Area 1.
A zone programmed ‘Yes’ for Silent Alarm will not cause any audible alarm event from a
programmable output OR from any keypad. However, a visual display will occur on the
keypad(s) which are assigned to the same area as the zone.
Menu 05 - Zone Definitions
(continued)
15
Keyfob
- Used when a wireless keyfob is enrolled into a receiver at this zone ID location.
16
No Alarm -
Intended for use in Whenever/And/Then rules from the Remote Programming RP software. This zone
type DOES NOT ACTIVATE any alarm and is not logged in the Event log. No reset is required.
17
Carbon Monoxide 24 hr
- Activates an immediate Carbon Monoxide alarm if tripped anytime (armed or disarmed).
The keypad will display the alarm as well as the event log. This type of alarm can be silenced/reset with a valid
User Code. The audible alarm can be set in “Cutoff Timers”.
18
Emergency 24 hr
- Similar to Def 17, this zone creates an alarm if tripped anytime (armed or disarmed).
19
Freeze Alarm 24 hr
- Similar to Def 17, this zone creates an alarm if tripped anytime (armed or disarmed).
20
Gas Alarm 24 hr
- Similar to Def 17, this zone creates an alarm if tripped anytime (armed or disarmed).
21
Heat Alarm 24 hr
- Similar to Def 17, this zone creates an alarm if tripped anytime (armed or disarmed).
22
Medical Alarm 24 hr
- Activates an immediate Medical alarm if tripped anytime (armed or disarmed).
23
Police Alarm w/Indication 24 hr
- Activates an audible Police (Holdup) alarm if tripped (armed or disarmed).
24
Police Alarm no Indication 24 hr
- Activates an non-audible Police (Silent) alarm if tripped (armed or disarmed).
25
Water Alarm 24 hr
- Activates an immediate Water alarm if tripped anytime (armed or disarmed).
26
Keyswitch Momentary
- Intended for a spring loaded momentary key switch. Toggles the armed state (disarmed/
armed) with each trip.
27
Keyswitch Momentary - Away Mode
- Intended for a spring loaded momentary key switch. Arms the area in the
AWAY mode with each trip.
28
Keyswitch Momentary - Stay Mode
- Intended for a spring loaded momentary key switch. Arms the area in the
STAY mode with each trip.
29
Keyswitch Momentary - Disarm Only
- For a spring loaded momentary key switch. Disarms with each trip.
30
Keyswitch On/Off (Maintained)
- Intended for a 2 position On/Off key switch. Arms the area in Open position.
Disarms the area in the Closed position.
31
Mute All Area Audibles
- For silencing all area audibles by a two-way listen-in module (other manufacturer).
32
Power Supervisory 24 hr
- For supervising an external power supply which provides alarm/trouble contacts. Wire
the power supply contacts to short the zone in a Low Battery event and open the zone in an AC Failure event.
33
Temperature
- For use with ELK-M1ZTS Temperature Sensors. Requires the use of Whenever/And/Then rules
from the ELK-RP software.
NOTE: This definition is for ZONES 1 thru 8 ONLY! Temperature zones must be set to
FAST LOOP (less that 200ms) response.
34
Analog
- For sensors that produce a variable voltage (0 to 12 volt range). Requires the Whenever/And/Then rules
from the ELK-RP software.
Def Zone Description
Operating Characteristics
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
ZN001 04: =No
r
Silent Alarm
0
EOL Supervised
, 2,200 Ohm resistor (Zones 1 - 8 are defaulted to Type=0)
1
Normally Closed only
. No resistor required.
2
Normally Open only
. No resistor required.
3
EOL Supervised with SECURITY ALERT on Short. (Burglar & Keyswitch Zones Only)
When control is disarmed a
Security “Day” Alert will occur if the zone wiring is SHORTED. Keypads will beep and display the alert and zone
name. Press Star key to silence. User code must be entered to reset/acknowledge the alert. When control is
armed an alarm will occur regardless of whether the zone wiring is OPENED or SHORTED.
4
EOL Supervised - 4 State Wiring, with SECURITY ALERT on Open or Short.
(Burglar & Keyswitch Zones Only)
Effective with firmware 4.3.5 this type provides
4 State Zone Wiring option,
which uses 2 series EOL resistors, 1 in
series with the loop and 1 in parallel with the alarm contacts. When control is disarmed a Security “Day” Alert will
occur if the zone wiring is OPENED (tamper switch) or SHORTED. Keypad(s) will beep and display the alert and
zone name. Ideal for tampering motions, etc. Press Star key to silence. User code must be entered to reset/
acknowledge the alert. When control is armed an alarm will occur regardless of whether the zone is OPENED or
SHORTED. NOTE: To define additional output/options on types 3 & 4 use the ElkRP Whenever/Then rules.
5
Fire, 4-Wire Smoke Detector
with 2,200 Ohm EOL resistor. Trouble on open, alarm on short. (Zones 1 to 8).
6
Fire, 2-wire Smoke Detector
with 680 Ohm EOL resistor. (ZONE 8 ONLY)
Type
Wiring Configuration
Operating Description
WWW.DIYALARMFORUM.COM