19
Empty conduits
Use separate conduits for the power line and the control leads.
Use an additional (separate) conduit for each induction loop.
The distance between the conduits should be as large as possible.
Drawing 5
Requirements regarding the foundation
A minimum concrete strength class of C20/25 (or higher)
The use of heavy duty anchor bolts (M12).
Observe the foundation dimensions quoted in this manual. The installation
distance between the barrier housing and the foundation edge has to be
approx. 100mm.
WARNING!
Risk of injury by insufficient fastening!
Tilting barrier housings can result in severe injuries.
Before installation ensure a safe stand of the barrier housing.
Do not lean the barrier boom against a wall or similar before installation.
Store the boom horizontally only.
Install the barrier housing as specified.
Use the recommended heavy duty anchor bolts M12, at least M10 is
required.
During maintenance check the housing for correct fastening on the
foundation.