© 14.11.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 10 TERRA 180/182 - 250/252 – 320/322
4.2.2. Emergency release
Damit die Notentriegelung einwandfrei arbeitet, muss der Torflügel mechanisch
spannungsarm in der Position AUF und ZU stehen.
Drawing 6
4.2.3. Emergency releasing
Open the cover of the cylinder lock below the gate support (see drawing 6). Insert the key
and turn it 90° anti-clockwise. Pull the emergency release lever downwards. The gate
opener is now released and the gate can be moved freely.
ATTENTION! The internal stops are not working now. The gate now can be
moved further than the regular end positions.
4.2.4. Engaging of emergency release
Push the emergency release lever up. Turn the key 90° clockwise. Remove the key and
close the cover of the cylinder lock. Move the gate until the emergency release engages.