© 14.11.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 28 TERRA 180/182 - 250/252 – 320/322
8.1.5. Sequence P5: Learning and deleting of code for radio
remote control for BT, BTG and MULTI
To learn a code the transmitter has to be operated. The code will then be stored. When
sequence
P5
is activated with the button
LERN
, an additional selection menu is displayed
for selecting the code. Move to the next point using button
BT.
Sub-sequence Function
C1
Radio remote control code for BT can be learned or deleted
C2
Radio remote control code for BTG can be learned or deleted
C3
Radio remote control code for MULTI can be learned or deleted
Next
Return to main sequence
Table 13
Sub-sequence is activated with button LERN. The display shows:
Display Corresponds
to:
- -
The selected radio remote control code is deleted and another can be learned.
oo
The selected radio remote control code is already stored and can be overwritten
or deleted
Table 14
To erase the radio remote control code, press and hold the button
BT
and additionally
push the button
LERN.
The radio remote control code is erased. Return to the sub
sequence follows automatically. If only the button
LERN
is pushed, then return to the sub
sequence follows immediately without erasing the code.
Radio remote control signal:
Receiving of a learned radio remote control signal is displayed through lighting of the right display dot.
8.1.6. Sequence P6: Automatic closure for complete opening
When sequence
P6
is activated by button
LERN
, the present value for stay-open time for
complete opening is displayed. Possible values are
--
(not activated),
01
up to
299
(for 1s -
299s). The value can be increased using button
BT
and decreased using button
BTG.
The decimal dots of the display are each equal to 100 (one lit dot = 100 /
two lit dots = 200).
Display (example) Corresponds to:
- -
Automatic closure is deactivated.
23
Automatic closure is activated. Stay-open time 23 seconds.
23.
Automatic closure is activated. Stay-open time 123 seconds.
2.3.
Automatic closure is activated. Stay-open time 223 seconds.
Table 15
Return to the learning sequence using button
LERN
.
When using automatic closure both wings close automatically after the learned stay-open
time has elapsed. The stay-open time starts elapsing when the last wing has reached the
position OPEN.
- When contact BS is opened, the automatic closure function is blocked.
- When the stay-open time has elapsed and the safety contact profile for direction
CLOSE (SLZ) is currently activated, the gate remains open. The elapsed stay-open
time will not be repeated. When the SLZ is not activated anymore and the stay-
open time has elapsed, the warning time prior to closing starts.