© 14.11.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG              Page 4                                   TERRA 180/182 - 250/252 – 320/322 

 

General notes of safety 

 

These operating instructions must be available on site at all times. It should be read thoroughly by all 
persons who use, or service the appliances. Improper usage or servicing or ignoring the operating 
instructions can be a source of danger for persons, or result in material damage. If the meaning of any part 
of these instructions isn’t clear, then please contact ELKA Torantriebe GmbH u. Co. Betriebs KG before you 
use the appliance.

 

This applies to all setup procedures, fault finding, disposal of material, care and servicing of the appliance.

 

The accident prevention regulations and applicable technical regulations (e.g. safety or electrical) and 
environment protection regulations of the country in which the appliance is used also apply.

 

All repairs on the appliances must be carried out by qualified persons. ELKA Torantriebe GmbH u. Co. 
Betriebs KG accepts no liability for damage which is caused by using the appliance for purposes other than 
those for which it is built.

 

ELKA Torantriebe GmbH u. Co. Betriebs KG cannot recognise every possible source of danger in advance. 
If the appliance is used other than in the recommended manner, the user must ascertain that no danger for 
himself or others will result from this use. He should also ascertain that the planned use will have no 
detrimental effect on the appliance itself. The appliance should only be used when all safety equipment is 
available and in working order. All faults which could be a source of danger to the user or to third persons 
must be eliminated immediately. All warning and safety notices on the appliances must be kept legible.

 

All electrical periphery equipment which is connected to the appliance must have a CE Mark, which ensures 
that it conforms to the relevant EEC regulations. Neither mechanical nor electrical alterations to the 
appliance, without explicit agreement of the manufacturer, are allowed. All alterations or extensions to the 
appliance must be carried out with parts which ELKA Torantriebe GmbH u. Co. Betriebs KG have defined as 
suitable for such alterations, and be carried out by qualified personnel. 

 

Any contravention of these conditions revokes the manufacturer’s guarantee and also the CE Mark and the 
user is alone responsible for the consequences.

 

Our service department is available to answer all queries about these conditions and, of course, about our 
appliances. 
 
 
 
 

 

We reserve the right to make technical improvements without prior notice.

 

 

 
 

 

The operation of the system within CEN countries must also be conformant with the European safety-relevant 
directives and standards. 

Summary of Contents for TERRA 180

Page 1: ...Installation and operating instructions Swing Gate Opener TERRA 180 182 TERRA 250 252 TERRA 320 322...

Page 2: ...tion plan of the controller MO36 ________________________________________________________22 8 Programming MO36 _________________________________________________________________________25 8 1 Learning...

Page 3: ...s intended During installation initial operation phase maintenance and testing of the controller the individually relevant regulations for safety and accident prevention have to be obeyed These are th...

Page 4: ...d manner the user must ascertain that no danger for himself or others will result from this use He should also ascertain that the planned use will have no detrimental effect on the appliance itself Th...

Page 5: ...on OPEN not required required for wings from2 500mm Power supply 230V 50Hz 230V 50Hz 230V 50Hz Operating voltage 24 V 24 V 24 V Duty cycle 50 50 50 Blocking when open closed Yes Yes Yes Soft Start and...

Page 6: ...g next to the gate either with set 1 or set 2 please use the measurements in the respective installation manual Drawing 1 Drawing 2 Please make sure that the gate wings can be moved easily and that th...

Page 7: ...5 removing of the adjustment clip Warning Please do not leave the emergency release key in the key lock Please do not remove the protective foil and the protective tape before installation has been c...

Page 8: ...plate 3 Support profile 4 Mounting plate 5 Gate support 6 Welding profile 7 Emergency release lever 8 Adjustment clip 4 1 Tools needed The following tools are needed on site for the installation 1 Tor...

Page 9: ...oncrete at least half way up the sides of the housing Note Do not remove the protective foil and the protective tape which covers the gap between the cover plate and the underfloor housing They protec...

Page 10: ...below the gate support see drawing 6 Insert the key and turn it 90 anti clockwise Pull the emergency release lever downwards The gate opener is now released and the gate can be moved freely ATTENTION...

Page 11: ...20 33 4 2 5 Installation at the gate Use the included welding profile There are 4 tapholes at one end of the welding profile The pivot point of the gate is located between these tapholes Pivot point D...

Page 12: ...inge Place the gate with the gate support onto the gearbox shaft which protrudes from the underfloor opener Push the lever up and lock the emergency release with the key see drawing 7 Drawing 9 Move t...

Page 13: ...opens first Max permitted force setting The original setting is force level 30 Change the force settings only when the original settings are not sufficient during learning The max permitted force set...

Page 14: ...ton LERN on the controller for approx 2 seconds The display shows P1 h Press the button LERN again The display now shows 1F i Now select the number of gate wings Confirm the displayed 1F for one wing...

Page 15: ...nto direction CLOSED until the end stop display P2 The gate is now in position CLOSED Should the gate now be in position OPEN the wires 4 and 5 of the motor connection cable at the 5 pin connection ha...

Page 16: ...number of gate wings Push button BT until it displays 2F Confirm the displayed 2F for two wings with the button LERN j The display shows HA manual operation k Now you can move each gate wing separate...

Page 17: ...o direction CLOSED until the end stop display P2 The gate is now in position CLOSED Should the gate now be in position OPEN the wires 4 and 5 of the motor connection cable at the 5 pin connection have...

Page 18: ...ks see 4 8f Adjustment clip Gear shaft Pinion Drawing 11 For perfect operation of the gate system it is now necessary to activate the pressure relief for the electromagnetic bolt a Press the button LE...

Page 19: ...ace the cover plate onto the underfloor housing ATTENTION Tighten the screws only 1 turn unto the point when the thread barely holds the screws Do not fasten the screws completely yet Piece by piece i...

Page 20: ...5 pin connection FAHR or GEH f Insert the adjustment clip from above into the gate opener The level part of the adjustment clip points away from the gear shaft g Make sure the marks on the pinions and...

Page 21: ...will have adverse effect on the motor performance Cross section 5 x 1 5 mm up to max 20 m Cross section 5 x 2 5 mm up to max 40 m Power supply 230Vac 50Hz single phase Connection By fixed wiring and...

Page 22: ...60W timer module ASU2 radio remote control receiver LERN magnetic lock 24Vdc max 1A pedestrian wing with 24Vdc motor with pulser N PE L1 LSI LSA SLA SLZ BT BTG BA BZ __ BS __ VP LSI LSA 8 2kO 8 2kO S...

Page 23: ...ulser for pedestrian wing IMPf pulser See motor Pulser for main wing SU Plug socket Connection for timer module ASU2 Funk Plug socket for receiver EKX1OF or receiver with decoder Integrated receiver f...

Page 24: ...or for one winged gates SCHLOSS 3 pin Connection for electromagnetic bolt or magnetic lock with 24Vdc max 1A WARN 2 pin Potential free contact for warning light 230Vac max 60W MULTI 2 pin Potential fr...

Page 25: ...tton LERN Sequence Function P1 Selection one wing two wings Adjusting of end stops Learning of safety contact profiles and photo cells connected Learning of running distance P2 Adjusting of force and...

Page 26: ...push the button LERN to continue The controller tests the safety contact strips and the photo cells It learns the type of the safety contact strips 8 2 k and the number of connected photo cells Only...

Page 27: ...for minimum speed up to 08 for maximum speed With button LERN the values may be increased with the button BTG they can be decreased Return to the learning sequence using button LERN Attention The max...

Page 28: ...without erasing the code Radio remote control signal Receiving of a learned radio remote control signal is displayed through lighting of the right display dot 8 1 6 Sequence P6 Automatic closure for c...

Page 29: ...ctivated Stay open time 23 seconds 23 Automatic closure is activated Stay open time 123 seconds 2 3 Automatic closure is activated Stay open time 223 seconds Table 16 Return to learning sequence using...

Page 30: ...g button LERN The warning light is only active when a gate wing is moving and during warning prior to opening and closing Display Warning time before opening Warning time before closing 00 No warning...

Page 31: ...esting Prior to every gate movement a photocell test may be performed The test consists of two phases During the first phase the supply of the transmitters is switched off The controller expects withi...

Page 32: ...ing distance P1 After this please check every single photocell for proper function Remark When a faulty photo cell is detected during photo cell testing or when an obstacle is present within the photo...

Page 33: ...A photo cell outside blocks the automatic closure function Only the signal from LSI photo cell inside removes the blocking and starts the stay open time When a vehicle passes through the gate from the...

Page 34: ...itional safety devices like photo cells and safety contact profiles are installed at the gate When sequence PD is activated by button LERN the present selection is displayed With the button BT the val...

Page 35: ...The controller has two integrated detectors with testing function according to EN954 1 category 2 for safety contact profiles with 8 2kOhm resistor for gate OPEN and CLOSE The status of the safety co...

Page 36: ...n OPEN command to the controller The gate cannot be closed as long as the timer is activated After the open time has elapsed the timer sends a CLOSE command to the controller Note When the timer sends...

Page 37: ...failed E4 Testing safety contact profile SLZ failed E5 Running distance exceeded gate was stopped Check end stoppers and re learn the running distance E6 The power supply limit for the external equip...

Page 38: ...s should be used in such a way that the gate can be seen during movement 13 Technical data MO36 13 1 Selection range of Parameter and Original settings Constant not changeable values Parameter Origina...

Reviews: