4. Installation
Important:
Warning! The controller needs to be disconnected while welding is
performed on the gate.
Internal stops have to be adjusted according to paragraph 4.4, even though when
external stops exist (see also paragraph 4.2 – emergency release).
Do not remove the adjustment clip before the adjustment of the internal
stops is completed (see paragraph 4.5 – removing of the adjustment clip).
Warning! Please do not leave the emergency release key in the key lock.
Please do not remove the protective foil and the protective tape before
installation has been completed (see paragraph 4.2).
In case external stops exist and are in use, adjust the wing/s in such a way
that they touch the external stops with the least possible tension.
The motor-connection cable (cross section 5x1.5mm²) should be laid through
a suitable conduit (shortest distance) to the next joint box. This mechanical
protection (conduit) has to be assured all the way to the joint box. Use a
suitable cable from the joint box onward.
Grommet
Drawing 3