Controller MO 36
31
main wing (or 1-winged
gates) with 24Vdc motor with
pulser
LS
-T
est
12Vd
c
24
V
dc
GN
D
BT
BTG
AMPEL
WARN 230Vac/max. 60W
MULTI 230Vac/max. 60W
LERN
magnetic lock 24Vdc/max 1A
electromagnetic bolt 24Vdc/max 1A
pedestrian wing with 24Vdc
motor with pulser
LS
I
LS
A
SL
A
SL
Z
BT
BT
G
BA
BZ
__
BS
__
VP
10.3
Output terminals of the controller
Drawing 23
Mark Connection
Function
SCHL
SCHL + GND
Connection for magnetic clamp (24Vdc, max. 1A)
GND
Mutual ground for magnetic clamp and electromagnetic bolt
SCHL
SCHL + GND
Connection for electromagnetic bolt (24Vdc, max. 1A)
GEH:
5-polig
Motor connection pedestrian wing
FAHR:
5-polig
Motor connection main wing
MULTI 2-polig Potential-free contact for multi-functional relay (230Vac, max.
WARN
2-polig
Potential-free contact for warning light (230Vac, max. 60W)
GND
Mutual ground 12V, 24V, and LS-TST
24V
24V + GND
24Vdc, stabilised (altogether with 12Vdc max. 300mA)
12V
12V + GND
12Vdc, stabilised (altogether with 24Vdc max. 300mA)
LS-TST
LS-TST + GND
Photoelectric barrier testing (24Vdc for transmitter)
Table 7
REMARK!
The ground of the direct current supply 24Vdc/12Vdc is connected to the controller
ground.