Controller MO 36
33
Mark Colour
Function
Normal
LSI green
Lights when photoelectric barrier INSIDE is
interrupted
OFF
LSA green
Lights when photoelectric barrier OUTSIDE is
interrupted
OFF
SLA
red
Lights when safety contact profile OPEN is activated
OFF
SLZ red
Lights when safety contact profile CLOSED is
activated
OFF
BT green
Lights when button BT (internal or external) is
activated
OFF
BTG green
Lights when button BT (internal or external) is
activated
OFF
BA
green
Lights when button BA is activated
OFF
BZ
green
Lights when button BZ is activated
OFF
BS green
Lights when button BS is NOT activated (BS-contact
n.c.)
ON
Vp
yellow
Lights when connected to supply voltage
ON
Display
red
2 x 7-segment display (
88
)
OFF
Table 9
10.6 Clip-on
module
10.6.1 Clip-on timer module ASU2 (optional)
The controller provides a socket for the timer module ASU2.
The timer has the following function:
When the timer is activated it works like an OPEN command. The gate cannot be closed as long as
the timer is activated.
When the timer is deactivated it works like a CLOSE signal. When the timer sends the CLOSE
command, the gate is closed immediately even when automatic closure is activated.
REMARK!
Do not connect anything but the optional module ASU2 at the terminal ASU2 on the
controller MO 36.