Controller MO 36
37
10.7.1 Sequence
p1
: Learning the running distance
Selecting system with 1 wing / system with 2 wings
Display Function
1f
To operate gates with one wing.
2f
To operate gates with two wings.
Tabelle 1
Confirm the selection with button
LERN
.
Then
ha
(manual operation) is displayed. The gate wings now can be operated in manual operation
to adjust the internal mechanical end stops inside the gate openers.
Button
BT
is used for the main
wing and
BTG
for the pedestrian wing in dead man’s mode. The first direction is always OPEN.
REMARK!
After adjustment of the end stops the wings should not be in either end position but at
least 50cm away, because the first movement goes into direction OPEN.
WARNUNG!
Risk of crushing by an automatic movement of the gate wings!
Individuls or objects within the danger area of the gate could get injured or damaged
respectively by the gate movement.
Ensure that no individuals or objects reside o rare present within the danger area during
the learning process.
REMARK!
After the next confirmation by button LERN the gate moves automatically.
Confirm the adjustment of the end stops using the button
LERN
.
Then
au
(automatic mode) is displayed. The controller tests the safety contact strips and the
photoelectric barriers. Then the gate moves automatically and learns the running time.
REMARK!
Only when this photoelectric barrier testing was successful, additional tests can be carried
out during future operation.