Controller MO 36
38
Gates with one wing:
During learning of the running time the wing first opens and then closes. The
wing stops at the end stop by force control.
Gates with two wings:
During learning of the running time the pedestrian wing opens first, then the
main wing opens, the main wing closes, and at last the pedestrian wing
closes. The wings stop at the end stops by force control.
REMARK!
During the learning of the running time the pressure relief of the electromagnetic bolt is
not in function. During learning of the distance the electromagnetic bolt is being activated
during each wing movement. Then returning to the main sequence follows automatically.
10.7.2 Sequence
p2
: Adjusting of force and speed
The force and speed can be adjusted for each wing and for opening and closing separately. When
sequence
p2
is activated by button
LERN
an additional selection menu for force values and speed
values (
f1
,
f2
, etc.) opens. Use button
BT
to move to the next selection menu point.
Selection
Selection menu points for force and speed
Sub-sequence Function
f1
Force to open the main wing
f2
Force to close the main wing
f3
Force to open the pedestrian wing. No function with gates with one wing.
f4
Force to close the pedestrian wing. No function with gates with one wing.
s1
Speed to open the main wing
s2
Speed to close the main wing
s3
Speed to open the pedestrian wing. No function with gates with one wing.
s4
Speed to close the pedestrian wing. No function with gates with one wing.
Table 12
User button
LERN
to activate the desired selection menu point. The present value for force (f for
force) or speed (
s
for speed) is displayed. Possible values are
01
(for minimum force) up to
99
(for
maximum force) or
01
(for minimum speed) up to
08
(for maximum speed). With button
BT
the
values may be increased, with button
BTG
they can be decreased. Confirm the current selection and
return to the selection menu or to the main learning sequence using button
LERN
.
WARNING!
In the learning sequence a force value (
f1
–
f4
) for the motor current is selected.
Therefore the operator is responsible that only a permitted force value is set (see Table 14).
Gate opener
Setting range in the learning sequence
ZENIT-S 300 / 302
f1
–
f4
= max. 55
ZENIT-S 450 / 452
f1
–
f4
= max. 65
Table 13