Controller MO 36
43
10.7.8 Sequence
p8
: Pre-warning
The
warning light
is only active, when a gate wing is moving or during warning prior to opening and
closing. Otherwise the warning light is not active.
Display
Pre-warning before opening
Pre-warning before closing
00
No warning time
No warning time
04
No warning time
4 seconds warning time
40
4 seconds warning time
No warning time
44
4 seconds warning time
4 seconds warning time
Table 18
REMARK!
When using the gate opener in connection with the electromagnetic bolt E 205, motor lock