44
10.7.9 Sequence
p9
: Photoelectric barrier function
When sequence
p9
is activated by button
LERN
, the present value for photoelectric barrier function is
displayed
.
Using button
BT
the desired operating mode can be selected.
To confirm the selection and to return to the learning sequence use button
LERN
.
Drawing 27
LS-Function
Photoelectric
barrier
Gate not moving Gate opens
Gate closes
L1 LSI Remains not
moving
Stops, opens
when free again
Stop, opens when
free again
LSA
Remains not
moving
Stop, opens
when free again
Stop, opens when
free again
L2 LSI Remains not
moving
Stop, opens
when free again
Stop, closes when
free again
LSA
Remains not
moving
Stop, opens
when free again
Stop, closes when
free again
L3 LSI Only closing
allowed
Stop, opens
when free again
No effect
LSA
Only opening
allowed
No effect
Stops and opens
immediately
Table 19