Controller MO 36
46
REMARK!
After the learning the operator has to check each photoelectric barrier for functioning.
REMARK!
When a faulty photoelectric barrier is detected during the testing or when an obstacle is
present within the photoelectric barrier, the gate can be opened and closed in emergency
mode.
10.7.11 Sequence
pb
: Lockage function of the photoelectric barriers
Drawing 29
A lockage function by photoelectric barriers is possible in connection with the automatic closure. To
activate this function use the learning sequence.
The lockage function is only activated when the gate is open.
When the gate reaches the end position OPEN, the lockage function is initialised, which means it is in
its initial state “Automatic closure by lockage function approved”.
When a vehicle first passes the photoelectric barrier LSA and then the photoelectric barrier LSI, then
the interruption of LSA blocks the automatic closure and the interruption of LSI unblocks it and starts
the stay-open time. When driving in the opposite direction, the blocking and unblocking occur
accordingly.
When sequence
pb
is activated by button
LERN
, the present selection is displayed. With button
BT
the desired value can be selected. To return to the learning sequence use button
LERN
.
Display Corresponds
to
of
Lockage function ist deactivated.
on
Lockage function is activated. When automatic closure is activated, a closing of
the gate wing / wings is only possible, after an incoming or outgoing vehicle has
passed both (LSA and LSI) photoelectric barriers.
Table 21