Controller MO 36
48
10.7.14 Sequence
pe
: Multi-function relay
The multi-functional relay on the controller is suitable for different modes. For the selection use the
learning sequence.
When sequence
pe
is activated by button
LERN
, the present selection is displayed. With button
BT
the desired selection can be chosen. To return to the learning sequence use button
LERN
.
REMARK!
During the learning function of the controller the relay is inactive.
Display Corresponds
to
r1
Push button mode:
The relay is active, as long as the radio remote control code MULTI is received.
r2
Toggle mode: The relay alternates between active and inactive with each
received radio remote control code MULTI.
r3
Light pulse mode:
The relay is active for 1 second, when BT, Funk BT, BTG, Funk BTG, BA, or BZ
are pushed.
r4
3-minute-light:
The relay is active for 180 second, when BT, Funk BT, BTG, Funk BTG, BA, or
BZ are pushed.
Table 24
10.7.15 Sequence
pf
: Return to origgnal setting
When sequence
pf
is activated by button
LERN
,
rE
is displayed.
To
return to original settings
press and hold button
BT a
nd push button
LERN
.
If only button
LERN
is pushed, you return to the learning sequence without changing any values. After
returning to original settings the running distance has to be relearned.
10.7.16 Sequence
pp
: Storing of data
When sequence
pp
is activated by button
LERN,
the implemented selections and changes are saved
power-failure-safe.
Automatic return from learning sequence to normal operation follows. The display turns off.