Normal operation
49
11 Normal
operation
Gate movement OPEN
1.
The electromagnetic bolt is activated (magnetic clamp is deactivated). If pressure relief for
electromagnetic bolt is activated, the gate moves against the end stop, to relief the pressure.
2.
Then the gate wing accelerates continuously until the selected end speed is reached. With
this speed the gate wing moves until a short distance before the end position OPEN. There
the speed is decelerated and the gate wing moves in slow mode against the end stop.
3.
The electromagnetic bolt is deactivated (magnetic clamp is activated).
Gate movement CLOSED
1.
The electromagnetic bolt is activated (magnetic clamp is deactivated). If pressure relief for
electromagnetic bolt is activated, the gate moves against the end stop, to relief the pressure.
2.
Then the gate wing accelerates continuously until the selected end speed is reached. With
this speed the gate wing moves until a short distance before the end position CLOSED.
There the speed is decelerated and the gate wing moves in slow mode against the end stop.
3.
The electromagnetic bolt is deactivated (magnetic clamp is activated).
Stop and restarting in an intermediate position
1.
The gate stops and the electromagnetic bolt is deactivated (magnetic clamp is activated).
2.
The opening and closing from an intermediate position proceeds similar to the normal
opening and closing, only without pressure relief of the electromagnetic bolt.
11.1
Operation with push button
1.
BA is for function OPEN. As long as BA is pushed, the gate cannot close.
2.
BZ is for function CLOSE.
3.
BS is for function STOP. As long as BS is pushed (contact BS is interrupted), no gate
movement is possible. Automatic closure is disabled by BS. When BS is released, a new
operating command has to be given.
4.
BT (internal, external, or Funk-BT) is for function OPEN-STOP-CLOSE-STOP, depending on
the present gate position or gate movement. For gates with 1 wing the main wing, for gates
with 2 wings the main and the pedestrian wing are activated.
5.
BTG (internal, external, or Funk-BTG) is for function OPEN-STOP-CLOSE-STOP,
depending on the present gate position or gate movement. For gates with 2 wings the
pedestrian wing is activated. For gates with 1 wing the button BTG has no function during
normal mode.
11.2
Operation with push button and automatic closure for both wings
1.
BT (internal, external, or Funk-BT) is for function OPEN. During gate movement BT is
without function. In position OPEN BT is for function CLOSE.
2.
BTG (internal, external, or Funk-BTG) is for function OPEN-STOP-CLOSE-STOP for the
pedestrian wing.
3.
BA is for function OPEN. As long as BA is pushed, the gate cannot close.
4.
BZ is for function CLOSE.
5.
As long as BS is pushed (contact BS is interrupted), no gate movement is possible.
Automatic closure is disabled by BS. When BS is released, a new operating command has
to be given.