Normal operation
50
11.3
Operation with push button and automatic closure fort he pedestrian wing
1.
BTG (internal, external, or Funk-BT) is for function OPEN for the pedestrian wing. During the
gate movement BTG is without function. In position OPEN BTG is for function CLOSE.
2.
BS is for function STOP. As long as BS is pushed (contact BS is interrupted), no gate
movement is possible. Automatic closure is disabled by BS. When BS is released, a new
operating command has to be given.
11.4
Emergency release during power failure
REMARK!
Use the emergency release only to mechanically disengage the gate from the gate opener
in case of power failure.
11.4.1 Disengaging the gate opener
WARNING!
Risk of crushing on protruding parts!
Body parts can be crushed between upper and lower half of the articulated arm.
Do not reach between or onto the upper or lower half of the articulated arm.
61°
61°
2
4
3
1
Drawing 30
Now disengage the articulated arm using the emergency release key (see Drawing 29). To do so
move the emergency release key from position 1 to position 2. Then turn the articulated arm towards
position 3; the driving lever is divided in an upper and a lower part.
WARNING!
Risk of crushing!
Do not leave the emergency release key in the keyhole. It could form another crushing
point. Remove the emergency release key after each use.